Thermal Analysis and Optimization for Cryopanel of NBI Cryocondensation Pump
基本信息来源于合作网站,原文需代理用户跳转至来源网站获取
摘要:
Excellent vacuum performance ensures a high beam transmission efficiency of the neutral beam injector (NBI). The vacuum performance is mainly determined by the cryoperfor-mance of the cryopanel of the cryocondensation pumps which are the main vacuum pumps of NBI. In order to optimize the cryoperformance, the requirements for the temperature distribution and the heat load of the cryopanel are analysed and the factors that affect the cryopanel's temperature distribution are studied. The results indicate that the temperature difference of the cryopanel can be reduced by fabricating the cryopanel with high thermal conductivity material, increasing its thickness and cutting the distance between the two upward cooling pipes. The results may be applied to a cryopanel cooled by forced flow liquid helium.