基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
AIM:To estimate the effects of human umbilical vein(HUV) implanted under the sclera of glaucoma model on intraocular pressure(IOP) lowering and to investigate its related mechanisms METHODS:A total of 20 human umbilical veins(HUV) were collected from healthy fetus umbilical core.After the establishment of glaucoma model in rabbits,human freeze-dried umbilical vein was implanted under the sclera during NPDS,while for control group,sclerostomy was performed without implant.The formation of the filtration bleb and IOP were detected every 24 hours before surgery and on day 3,7,10 and 14 after surgery.Handheld pen-type Tono-penⅡtonometer was used to measure IOP after topical anesthesia treatment.Each measurement has three duplicates.The incision recovery,filtration,conjunctiva congestion and anterior chamber inflammation were observed everyday after surgery.RESULTS:IOP was decreased dramatically with less inflammation than traditional sclerostomies with the application of HUV.The significant differences of IOP between the NPDS with and without HUV implant groups were shown up from 10 days after surgery.The average IOP in NPDS without HUV implant was 14.25mmHg,while for NPDS with HUV implant group,it was 12.30mmHg.This structure of filtration bleb,which allowed the aqueous humor to leave the eye,was formed for any type of surgery.However,1-2 weeks later,filtration bleb was still existed in the group of sclerostomy with HUV implant and more stable than that of the surgery without HUV implant.Histological observations were performed on day 3,7 and 14 after surgery.For the eyes under sclerostomy with HUV implant,HUV lumina was shown up on 3 days after surgery with few fibroblast cells near the sclera.On 7 days after surgery,HUV lumina was stably maintained but with obvious fibroblast cells and inflammatory cell.On 14 days after surgery,HUV lumina was still clearly observed but with scarring formation,which suggests that the IOP lowering effects might result from an effective drainage structure formation.CONCLUSION:HUV
推荐文章
脐静脉导管封管效果的临床观察
脐静脉导管
封管
新生儿
非透明贴膜在深静脉置管护理中的使用效果观察
非透明贴膜
深静脉置管
局部感染
皮肤过敏
品管圈对降低深静脉置管敷料非计划性更换率的效果观察
品管圈
深静脉置管
敷料
非计划性更换
脐静脉置管两种缝扎固定方法的效果比较
改良式脐带缝扎固定法
脐静脉置管
比较
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 为在在兔子的非渗透的深 sclerostomy 的人的脐的静脉的申请的 IOP 阴沉的效果
来源期刊 国际眼科杂志:英文版 学科 医学
关键词 IOP-lowering non-penetrating DEEP sclerostomy human UMBILICAL VEIN
年,卷(期) 2011,(1) 所属期刊栏目
研究方向 页码范围 55-57
页数 3页 分类号 R779.6
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (33)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2008(1)
  • 参考文献(1)
  • 二级参考文献(0)
2011(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
IOP-lowering
non-penetrating
DEEP
sclerostomy
human
UMBILICAL
VEIN
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
国际眼科杂志:英文版
月刊
2222-3959
西安市友谊东路269号
出版文献量(篇)
2720
总下载数(次)
2
总被引数(次)
0
论文1v1指导