基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
AIM:To investigate intra-operator variability of semiquantitative perfusion parameters using dynamic contrast-enhanced ultrasonography(DCE-US),following bolus injections of SonoVue.METHODS:The in vitro experiments were conducted using three in-house sets up based on pumping a fluid through a phantom placed in a water tank.In the in vivo experiments,B16F10 melanoma cells were xenografted to five nude mice.Both in vitro and in vivo,images were acquired following bolus injections of the ultrasound contrast agent SonoVue(Bracco,Milan,Italy) and using a Toshiba Aplio ultrasound scanner connected to a 2.9-5.8 MHz linear transducer(PZT,PLT 604AT probe)(Toshiba,Japan) allowing harmonic imaging('Vascular Recognition Imaging') involving linear raw data.A mathematical model based on the dye-dilution theory was developed by the Gustave Roussy Institute,Villejuif,France and used to evaluate seven perfusion parameters from time-intensity curves.Intra-operator variability analyses were based on determining perfusion parameter coefficients of variation(CV).RESULTS:In vitro,different volumes of SonoVue were tested with the three phantoms:intra-operator variability was found to range from 2.33% to 23.72%.In vivo,experiments were performed on tumor tissues and perfusion parameters exhibited values ranging from 1.48% to 29.97%.In addition,the area under the curve(AUC) and the area under the wash-out(AUWO) were two of the parameters of great interest since throughout in vitro and in vivo experiments their variability was lower than 15.79%.CONCLUSION:AUC and AUWO appear to be the most reliable parameters for assessing tumor perfusion using DCE-US as they exhibited the lowest CV values.
推荐文章
优化网络设备维护提高数据通信传输质量
网络设备
数据通信
传输质量
网络故障
广东省数据通信设备雷害防护技术初探
DDN
数据设备
雷电电磁脉冲
隔离连接网
雷电防护
防护原则与措施
数据通信的发展综述
数据通信
多媒体通信
IP
一种嵌入式手持设备的无线数据通信模块扩展方法
无线数据通信
手持设备
Windows CE 操作系统
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 在用数据通信设备美国的灌注参数大小的 intra 操作员可变性的评价
来源期刊 世界放射学杂志:英文版(电子版) 学科 医学
关键词 Dynamic CONTRAST-ENHANCED ultrasonography Intra-operator variability Functional imaging SEMI-QUANTITATIVE PERFUSION parameters Linear raw data Quantification
年,卷(期) 2011,(3) 所属期刊栏目
研究方向 页码范围 70-81
页数 12页 分类号 R739.5
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2011(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
Dynamic
CONTRAST-ENHANCED
ultrasonography
Intra-operator
variability
Functional
imaging
SEMI-QUANTITATIVE
PERFUSION
parameters
Linear
raw
data
Quantification
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
世界放射学杂志:英文版(电子版)
月刊
1949-8470
北京市朝阳区东四环中路62号楼远洋国际中
出版文献量(篇)
785
总下载数(次)
1
总被引数(次)
0
论文1v1指导