基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
A simple, sensitive and precise green high-performance liquid chromatographic method including on-line pre-column oxidation combined by column switching with a short Hypersil ODS analytical column (100 mm × 4.0 mm i.d.) for enrichment and separation was developed and validated to determine low levels of methotrexate (MTX). The method was based on oxidative cleavage of MTX into highly fluorescence products, 2,4-diaminopteridine-6-carboxaldehyde and the corresponding 2,4-diaminopteridine-6-carboxylic acid, during the flow of phosphate buffer (0.04 M, pH 3.4) containing the analyte through the packed reactor of cerium (IV) trihydroxyhydroperoxide (CTH) at a flow-rate of 0.2 mL/min and 40℃. The fluorescent products were enriched on the head of ODS analytical column for the final separation. The separation was performed at room temperature using an environmentally friendly mobile phase consisting of ethanol and phosphate buffer (0.04 M, pH 3.4) in the ratio of 10:90 (v/v). The eluent was monitored at emission and excitation wavelengths of 463 and 367 nm, respectively. The method was successfully applied, without any interference from the excipients, for the determination of drug in tablets and vials with a detection limit of 0.06 ng/mL from 500 ?L of sample MTX.
推荐文章
Snowball Earth at low solar luminosity prevented by the ocean–atmosphere coupling
Faint Young Sun paradox
Carbon dioxide
Earth system
Siderite
基于层次分析法权重和灰色服务器负载预测的云计算on-line迁移策略
层次分析法
云计算
虚拟机迁移
负载均衡
服务器
The enhanced element enrichment in the supercritical states of granite–pegmatite systems
Granites
Pegmatites
Supercritical state
Extreme element enrichment
Using Geomechanical Method to Predict Tectonic Fractures in Low-Permeability Sandstone Reservoirs
Low-permeability sandstone reservoir
Fracture parameters
Geomechanical method
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Coupling of on-Line Pre-Column Oxidative Cleavage and Solid-Phase Enrichment with Liquid Chromatography Using an Eco-Friendly Analytical Procedure to Determine Low Levels of Methotrexate
来源期刊 分析科学方法和仪器期刊(英文) 学科 化学
关键词 Cerium (IV) Trihydroxyhydroperoxide HPLC METHOTREXATE ODS ANALYTICAL Column ON-LINE Pre-Column Oxidative CLEAVAGE
年,卷(期) fxkxffhyqqkyw_2012,(4) 所属期刊栏目
研究方向 页码范围 194-202
页数 9页 分类号 O6
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2012(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
Cerium
(IV)
Trihydroxyhydroperoxide
HPLC
METHOTREXATE
ODS
ANALYTICAL
Column
ON-LINE
Pre-Column
Oxidative
CLEAVAGE
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
分析科学方法和仪器期刊(英文)
季刊
2164-2745
武汉市江夏区汤逊湖北路38号光谷总部空间
出版文献量(篇)
125
总下载数(次)
0
论文1v1指导