AIM:To evaluate the feasibility of intravenous contrastenhanced C-arm computed tomography(CT) for assessing ablative areas and margins of liver tumors.METHODS:Twelve patients(5 men,7 women;mean age,69.5 years) who had liver tumors(8 hepatocellular carcinomas,4 metastatic liver tumors;mean size,16.3 mm;size range,8-20 mm) and who underwent percutaneous radiofrequency ablations(RFAs) with a flatdetector C-arm system were retrospectively reviewed.Intravenously enhanced C-arm CT and multidetector computed tomography(MDCT) images were obtained at the end of the RFA sessions and 3-7 d after RFA to evaluate the ablative areas and margins.The ablated areas and margins were measured using axial plane images acquired by both imaging techniques,with prior contrast-enhanced MDCT images as the reference.The sensitivity,specificity,and positive and negative predictive values of C-arm CT for detecting insufficient ablative margins(【 5 mm) were calculated.Statistical differences in the ablative areas and margins evaluated with both imaging techniques were compared using a paired t-test.RESULTS:All RFA procedures were technically successful.Of 48 total ablative margins,19(39.6%) and 20(41.6%) margins were found to be insufficient with C-arm CT and MDCT,respectively.Moreover,there were no significant differences between these 2 imaging techniques in the detection of these insufficient ablative margins.The sensitivity,specificity,and positive and negative predictive values for detecting insufficient margins by C-arm CT were 90.0%,96.4%,94.7% and 93.1%,respectively.The mean estimated ablative areas calculated from C-arm CT(462.5 ± 202.1 mm 2) and from MDCT(441.2 ± 212.5 mm 2) were not significantly different.The mean ablative margins evaluated by C-arm CT(6.4 ± 2.2 mm) and by MDCT(6.0 ± 2.4 mm) were also not significantly different.CONCLUSION:The efficacy of intravenous contrastenhanced C-arm CT in assessing the ablative areas and margins after RFA of liver tumors is nearly equivalent to that of MDCT.
推荐文章
胶片非线性特性对电子断层摄影术成像质量的影响
电子断层摄影术
三维重构
图像质量
胶片
非线性
计算机仿真
超声和X线摄影术诊断早期乳腺癌价值的Meta分析
乳腺肿瘤
超声检查
乳房
乳房X线摄影术
Meta分析
乳腺癌临床体检、超声检查和乳腺X线摄影术的诊断价值
乳腺肿瘤
X线摄影术
超声检查
病理类型
诊断价值
周围型肺癌的多层计算机断层摄影术诊断
肺肿瘤
体层摄影术
螺旋计算机
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 对有静脉内的提高对比的 C 手臂的肝肿瘤的脱离边缘评价计算了断层摄影术
来源期刊 世界放射学杂志:英文版(电子版) 学科 医学
关键词 RADIOFREQUENCY ablation CONE-BEAM COMPUTED tomography Safety MARGIN Liver NEOPLASMS
年,卷(期) 2012,(3) 所属期刊栏目
研究方向 页码范围 109-114
页数 6页 分类号 R735.7
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2012(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
RADIOFREQUENCY
ablation
CONE-BEAM
COMPUTED
tomography
Safety
MARGIN
Liver
NEOPLASMS
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
世界放射学杂志:英文版(电子版)
月刊
1949-8470
北京市朝阳区东四环中路62号楼远洋国际中
出版文献量(篇)
785
总下载数(次)
1
总被引数(次)
0
论文1v1指导