基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
Background and Purpose: The display resolution of the Apple iPad? is 1024 × 768 pixels, which is greater than that required for generating the typical CT or MRI images. The purpose of this study is to determine if specific CT and MR sequences can be interpreted accurately on mobile device/PACS software platforms when compared to a traditional stationary high resolution monitor/PACS radiological workstation. If so, this allows radiologists to provide comparable interpretation as if they were onsite at an imaging center or hospital. Materials and Methods: This study is an investigator initiated, single site, retrospective, nonrandomized, IRB approved study. Five radiologists were included in this study. Each independently interpreted specific CT and MR sequences on traditional high-resolution LCD monitors via eFilm? software as well as an iPad? mobile device using Osirix? software program. Repeat interpretations were performed, with 4 weeks minimum interval between interpretations of each patient. This investigation included: 50 patients with CTA perfusion imaging, 50 patients with MRI of the brain, and 50 patients with MRI of the spine, which were image study orders generated through emergency room requests. Subsequently, interpretive results of each radiologist for each patient were statistically compared to evaluate for intra-observer and inter-observer reliability. Results: The parameters set within the CTA perfusion brain studies demonstrated excellent intra-observer variability. All of the parameters within the MRI brain studies demonstrated excellent intra-observer variability with a Cohen’s kappa value > 0.75. The Cohen’s kappa values for the board certified neuroradiologist demonstrated excellent variability for all parameters;the resident radiologists had good variability, with a majority of kappa values near 0.75. Conclusions: The data and statistical analysis demonstrated that portable mobile devices such as the Apple iPad? can display adequate resolution of CT and MRI sequences to accurately diagn
推荐文章
PACS系统中的DICOM标准概述
DICOM
医学图像通讯
运行机制
螺旋CT工作站与PACS联机通信及其应用
计算机联机通信
影像存档与传输系统
放射学信息系统
医院PACS系统的效益研究
PACS
效益
诊断方式
医疗效率
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Intra and Inter-Observer Reliability of Mobile Tablet PACS Viewer System vs. Standard PACS Viewing Station-Diagnosis of Acute Central Nervous System Events
来源期刊 放射学期刊(英文) 学科 医学
关键词 TELERADIOLOGY TELEMEDICINE Cloud Network PACS MOBILE Device Emergency ACUTE Stroke
年,卷(期) 2013,(2) 所属期刊栏目
研究方向 页码范围 91-98
页数 8页 分类号 R73
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2013(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
TELERADIOLOGY
TELEMEDICINE
Cloud
Network
PACS
MOBILE
Device
Emergency
ACUTE
Stroke
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
放射学期刊(英文)
季刊
2164-3024
武汉市江夏区汤逊湖北路38号光谷总部空间
出版文献量(篇)
256
总下载数(次)
0
总被引数(次)
0
论文1v1指导