The spatial resolution of the gamma-rays camera was measured on a60Co gamma-rays source with edge method. The gamma-rays camera is consisting with rays-fluorescence convertor, optical imaging system, MCP image intensifier, CCD camera, electronic control system and other devices, and is mainly used in the image diagnostics of the intense pulse radiation sources [1]. Due to the relatively big quantum detective efficiency (DQE) and quantum gain of the gamma-rays, etc., the experimental data were processed by averaging multiple images and fitting curves. According to the experimental results, the spatial resolution MTF (modulation transfer function) at the 10% intensity was about 2lp/mm. Meanwhile, because of the relatively big dispersion effects of the fluorescence transmissions in the scintillator and the optical imaging system, the maximal single-noise ratio (SNR) of the camera was found to be about 5:1. In addition, the spatial resolution of the camera was measured with pulse X-rays with 0.3MeV in average energy and exclusion of the effects of secondary electrons from consideration. Accordingly, the spatial resolution MTF at the 10% intensity was about 5lp/mm. This could be an additional evidence to verify the effects of secondary electrons induced by the 1.25MeV gamma-rays in the scintillator upon the spatial resolution. Based on our analysis, the dispersion sizes of the secondary electrons in the scintillator are about 0.4mm-0.6mm. Comparatively, as indicated by the detailed analysis of the spatial resolutions of the MCP image intensifier and CCD devices, both of them have little effect on the spatial resolution of the gamma-rays camera that could be well neglected.
推荐文章
Are spatial distributions of major elements in soil influenced by human landscapes?
Major elements
Spatial distribution
Geographical background
Human landscape
Geographic information system
Remote sensing
The Preliminary Research on Rupture and Factors Affecting Rupturing of the Hoh Sai Hu Segment in Eastern
东昆仑断裂带
破裂行为
库赛湖
影响因素
地震复发间隔
平均滑动速率
摩擦系数
青藏高原北部
Hydrogeochemical evaluation and statistical analysis of groundwater of Sylhet, north-eastern Banglad
Arsenic
Groundwater
Hydrogeochemistry
Multivariate statistics
Spatial distribution
Temporal and spatial characteristics of dissolved organic carbon in the Wujiang River, Southwest Chi
Carbon cycle
Dissolved organic carbon
Dam-building effect
The Wujiang River
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Evaluation of Major Factors Affecting Spatial Resolution of Gamma-Rays Camera
来源期刊 分析科学方法和仪器期刊(英文) 学科 医学
关键词 GAMMA-RAYS CAMERA Point Spread Function (PSF) GAMMA-RAYS IMAGE Detector Scintillator MCP IMAGE INTENSIFIER CCD
年,卷(期) fxkxffhyqqkyw_2013,(4) 所属期刊栏目
研究方向 页码范围 227-233
页数 7页 分类号 R73
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2013(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
GAMMA-RAYS
CAMERA
Point
Spread
Function
(PSF)
GAMMA-RAYS
IMAGE
Detector
Scintillator
MCP
IMAGE
INTENSIFIER
CCD
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
分析科学方法和仪器期刊(英文)
季刊
2164-2745
武汉市江夏区汤逊湖北路38号光谷总部空间
出版文献量(篇)
125
总下载数(次)
0
论文1v1指导