基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
AIM:To correlate dual-energy computed tomography(DECT) pulmonary angiography derived iodine maps with parameter maps of quantitative pulmonary perfusion magnetic resonance imaging(MRI).METHODS:Eighteen patients with pulmonary perfusion defects detected on DECT derived iodine maps were included in this prospective study and additionally underwent time-resolved contrast-enhanced pulmonary MRI [dynamic contrast enhanced(DCE)-MRI].DCE-MRI data were quantitatively analyzed using a pixel-by-pixel deconvolution analysis calculating regional pulmonary blood flow(PBF),pulmonary blood volume(PBV) and mean transit time(MTT) in visually normal lung parenchyma and perfusion defects.Perfusion parameterswere correlated to mean attenuation values of normal lung and perfusion defects on DECT iodine maps.Two readers rated the concordance of perfusion defects in a visual analysis using a 5-point Likert-scale(1 = no correlation,5 = excellent correlation).RESULTS:In visually normal pulmonary tissue mean DECT and MRI values were:22.6 ± 8.3 Hounsfield units(HU);PBF:58.8 ± 36.0 mL/100 mL per minute;PBV:16.6 ± 8.5 mL;MTT:17.1 ± 10.3 s.In areas with restricted perfusion mean DECT and MRI values were:4.0 ± 3.9 HU;PBF:10.3 ± 5.5 mL/100 mL per minute,PBV:5 ± 4 mL,MTT:21.6 ± 14.0 s.The differences between visually normal parenchyma and areas of restricted perfusion were statistically significant for PBF,PBV and DECT(P 【 0.0001).No linear correlation was found between MRI perfusion parameters and attenuation values of DECT iodine maps(PBF:r = 0.35,P = 0.15;PBV:r = 0.34,P = 0.16;MTT:r = 0.41,P = 0.08).Visual analysis revealed a moderate correlation between perfusion defects on DECT iodine maps and the parameter maps of DCE-MRI(mean score 3.6,k 0.45).CONCLUSION:There is a moderate visual but not statistically significant correlation between DECT iodine maps and perfusion parameter maps of DCE-MRI.
推荐文章
小脑梗塞的CT和MRI诊断价值
小脑梗塞
计算机断层成像
磁共振成像
肾上腺良恶性肿瘤CT MRI诊断
肾上腺肿瘤 良性 恶性 CT MRI 诊断
胰腺囊腺瘤的CT MRI诊断分析
胰腺
囊腺瘤
体层摄影术
磁共振成像
阴囊闭合性损伤的CT与MRI诊断价值
阴囊睾丸损伤
体层摄影术
X线计算机
磁共振成像
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Correlation analysis of dual-energy CT iodine maps with quantitative pulmonary perfusion MRI
来源期刊 世界放射学杂志:英文版(电子版) 学科 医学
关键词 DUAL-ENERGY COMPUTED tomography Timeresolved magnetic resonance imaging PULMONARY PERFUSION IODINE MAPS
年,卷(期) 2013,(5) 所属期刊栏目
研究方向 页码范围 202-207
页数 6页 分类号 R445.2
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2013(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
DUAL-ENERGY
COMPUTED
tomography
Timeresolved
magnetic
resonance
imaging
PULMONARY
PERFUSION
IODINE
MAPS
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
世界放射学杂志:英文版(电子版)
月刊
1949-8470
北京市朝阳区东四环中路62号楼远洋国际中
出版文献量(篇)
785
总下载数(次)
1
总被引数(次)
0
论文1v1指导