基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
AIM: To record aberrations with a corneal topographic device on the anterior surface of the cornea at different time-points prior to wearing and following discontinued use of rigid gas permeable (RGP) contact lenses. The effect of wearing RGP on the anterior surface of the cornea was discussed to provide guidance for clinical refractive error correction.METHODS: The study objects were 24 eyes from 24 patients. All patients underwent identical examination procedures prior to lens use, as well as afterwards, including slit-lamp examination, non-contact tonometer measurement, computer optometry and corneal curvature measurement, subjective refraction test, and corneal topography analysis. The patients wore contact lenses everyday for 1 month and then discontinued. Corneal topographies were recorded at certain time points of 30 minutes, 1 day, 3, 7 and 14 days following use.RESULTS: Total corneal aberration at each time point following discontinued use of RGP contact lenses was less than the time point prior to use. Detailed results were as follows: root mean square (RMS) (pre)=(1.438± 0.328)μm, RMS (30 minutes) =(1.076 ±0.355)μm, RMS (1 day) =(1.362 ±0.402)μm, RMS (3 days) =(1.373 ±0.398)μm, RMS (7 days) =(1.387 ±0.415)μm, and RMS (14 days) = (1.430±0.423)μm. Results showed that at 30 minutes after discontinued use of RGP contact lenses, almost all 2 ndand 3 rd-order aberrations change. Quadrafoil Z10 and spherical Z12 of the 4 th-order were also changed. Alterations to Z5, Z6, and Z12 at 1 day after discontinued use were significant differences compared with the time period prior to RGP use: Z5 and Z6 decreased, and Z12 increased slightly. Z5 and Z6 remained decreased at 3 days after discontinued use, but Z9 and Z10 continued to increase and Z12 returned to levels prior to RGP use. At 14 days after discontinued use, all aberrations were notsignificantly different from the values prior to use.CONCLUSION: The use RGP contact lenses greatly reduced total aberration of the anterior surface of the cornea. C
推荐文章
应急情境下追随者特质与追随效果的相关性研究
应急救援
追随者特质
追随效果
相关性
回归分析
配戴隐形眼镜对角膜厚度的影响
准分子激光原位角膜磨镶术(LASIK)
角膜测厚仪
隐形眼镜
角膜水肿
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 角膜的前面的表面追随者的错误变化中止了僵硬煤气的可渗透的隐形眼镜的使用
来源期刊 国际眼科杂志:英文版 学科 医学
关键词 ABERRATION rigid gas PERMEABLE contact LENS CORNEA
年,卷(期) 2013,(2) 所属期刊栏目
研究方向 页码范围 178-182
页数 5页 分类号 R778.3
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (16)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2013(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
ABERRATION
rigid
gas
PERMEABLE
contact
LENS
CORNEA
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
国际眼科杂志:英文版
月刊
2222-3959
西安市友谊东路269号
出版文献量(篇)
2720
总下载数(次)
2
总被引数(次)
0
论文1v1指导