基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
AIM:To explore a simple and low-cost self-made disposable flexible iris retractor and study its clinical efficacy and safety in small pupil phacoemulsification.METHODS:Polyproplyenesutureandscalpacupuncture were used to make iris retractor.A prospective study were carried on 50 patients(50 eyes)with a maximally dilated pupil size of 2.5-4.0 mm which underwent phacoemulsification using this self-made iris retractor.Another 50 cases of phacoemulsification with normal pupil size sever as control group.The mean operation time,ultrasound time and ultrasonic power,volume of irrigation fluid were documented intraoperatively.The visual acuity,pupil size and complication were observed on 1d,1wk,1mo and 1y after operation.Corneal endothelial cell was measured at 1mo postoperatively.·RESULT:Pupils could be expanded to approximately4.5-5.5 mm with our self-made iris retractor in operation.No serious postoperative complication was found.Most(88%)of the pupils returned round or oval shape,light reflex restored to varying degrees at the first day after surgery.Best corrected visual acuity stabilized in 37 eyes(74%)at one day,in 43 eyes(86%)at one week,in 44eyes(88%)at one month and 46 eyes(92%)at one year.Compared with the control,more time was needed to complete the operation in the small pupil group.There was no significant difference of the mean ultrasound time,ultrasonic power,volume of irrigation fluid requiredand corneal endothelial cell loss in 1mo follow up between the two groups.CONCLUSION:Our self-made disposable flexible iris retractor could be easy obtained preoperatively or intraoperatively.It performed both safety and efficacy in our clinical trials.This simple self-made device has shown economic and practical values,especially in primary care hospital of the less developed districts.
推荐文章
探讨LTE small cell回传切换策略
LTE-small cell
CSG
回传切换
延迟
一种基于用户行为的Self集构造和演化方法
计算机免疫
演化计算
计算机安全
入侵检测
Small RTOS51下CAN总线数据收发实现
CAN总线
Small RTOS51
实时操作系统
SJA1000
基于4G Small Cell的商场无线智能导购系统设计
移动通信网
SmallCell
本地IP接入
商场智能导购
内容精准推送
目标点智能导引
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 A self-made disposable iris retractor in small pupil phacoemulsification
来源期刊 国际眼科杂志:英文版 学科 医学
关键词 smallpupil irisretractor PHACOEMULSIFICATION
年,卷(期) 2014,(2) 所属期刊栏目
研究方向 页码范围 288-292
页数 5页 分类号 R776.1
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2014(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
smallpupil
irisretractor
PHACOEMULSIFICATION
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
国际眼科杂志:英文版
月刊
2222-3959
西安市友谊东路269号
出版文献量(篇)
2720
总下载数(次)
2
论文1v1指导