Pseudo-global tomography for local micro-computed tomography with high-brightness synchrotron X-rays
基本信息来源于合作网站,原文需代理用户跳转至来源网站获取
摘要:
The computed tomography imaging of a local region inside a sample with a size larger than the field of view is particularly important for synchrotron X-ray imaging.In this letter,an improved algorithm is proposed to reconstruct the local structure inside a sample using almost completely local data.The algorithm significantly reduces the X-ray radiation dose and improves computational efficiency.Simulation results show that the new algorithm works well and has a higher reconstruction precision than previous methods,as confirmed by experimental results carried out at the Shanghai Synchrotron Radiation Facility.