基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
The purpose of this study was to evaluate the impact of polystyrene divinylbenzene copolymer HPLC columns on the chromatographic performance of the USP compendial method for doxycycline hyclate. The compendial method was implemented based on the assessment of the chromatographic performance of six USP defined L21 polystyrene divinylbenzene HPLC columns. Modifications to the method were based on USP for chromatography. The method was validated for the determination of doxycycline hyclate and its impurities in commercially available drug products. A number of different polystyrene-divinylbenzene columns were tested and failed to provide selectivity for the resolution of doxycycline and its impurities. Separation was optimally achieved on an Agilent PLPR-S column (250 × 4.6 mm, 8 μm) by using an Agilent 1260 series HPLC system. Doxycycline hyclate and its impurities were eluted isocratically at a flow rate of 1 mL/min with mobile phase and detected at 270 nm. The column temperature was maintained at 60oC. The method was validated according to USP category I requirements for Assay. Validation acceptance criteria were met in all cases. The analytical range for doxycycline hyclate was 50 - 250 μg/mL and the linearity was r2 > 0.999 over three days. The method was determined to be specific. Both accuracy (95.1% - 102.4%) and precision (0.50% - 4.8%) were established across the analytical range for low, intermediate and high QC concentrations. Method applicability was demonstrated by analyzing marketed products of doxycycline hyclate, in which results showed potency meeting USP acceptance criteria. In conclusion, this study described the remarkable differences in selectivity that were encountered during the implementation phase for the compendial methods for doxycycline and its impurities in marketed products and it could be used in the future to assss the product quality of doxycycline hyclate capsules stored in the National stockpiles.
推荐文章
A re-assessment of nickel-doping method in iron isotope analysis on rock samples using multi-collect
Fe isotope
Ni-doping
Stable isotope
Precision and accuracy
Mass bias correction
Pseudo-high mass resolution
Using Geomechanical Method to Predict Tectonic Fractures in Low-Permeability Sandstone Reservoirs
Low-permeability sandstone reservoir
Fracture parameters
Geomechanical method
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 A Comparative Evaluation of Polystyrene Divinylbenzene Copolymer HPLC Columns on the Chromatographic Performance of the Compendial Method for Doxycycline Hyclate Capsules: Implications for Method Implementation of a Medical Countermeasure Medication
来源期刊 分析科学方法和仪器期刊(英文) 学科 医学
关键词 DOXYCYCLINE 4-Epidoxycycline 6-Epidoxycycline Metacycline POLYSTYRENE-DIVINYLBENZENE
年,卷(期) fxkxffhyqqkyw_2015,(3) 所属期刊栏目
研究方向 页码范围 23-34
页数 12页 分类号 R73
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2015(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
DOXYCYCLINE
4-Epidoxycycline
6-Epidoxycycline
Metacycline
POLYSTYRENE-DIVINYLBENZENE
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
分析科学方法和仪器期刊(英文)
季刊
2164-2745
武汉市江夏区汤逊湖北路38号光谷总部空间
出版文献量(篇)
125
总下载数(次)
0
论文1v1指导