基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
The present study utilized a porcine model for qualitative and quantitative assessment of the diagnostic quality of non-contrast abdominal computed tomography (CT) images generated by Adaptive Statistical Iterative Reconstruction (ASIR, GE Healthcare, Waukesha, Wisconsin, USA), Model-Based Iterative Reconstruction (GE company name VEO), and conventional Filtered back projection (FBP) technique. Methods: Multiple CT whole-body scans of a freshly euthanized pig carcass were performed on a 64-slice GE CT scanner at varying noise indices (5, 10, 15, 20, 30, 37, 40, 45), and with three different algorithms (VEO, FBP, and ASIR at 30%, 50%, and 70% levels of ASIR-FBP blending). Abdominal CT images were reviewed and scored in a blinded and randomized manner by two board-certified abdominal radiologists. The task was to evaluate the clarity of the images according to a rubric involving edge sharpness, presence of artifact, anatomical clarity (assessed at four regions), and perceived diagnostic acceptability. This amounted to seven criteria, each of which was graded on a scale of 1 to 5. A weighted formula was used to calculate a composite score for each scan. Results: VEO outperforms ASIR and FBP by an average of 0.5 points per the scoring system used (p < 0.05). Above a threshold noise index of 30, diagnostic acceptability is lost by all algorithms, and there is no diagnostic advantage to increasing the dose beyond a noise index of 10. Between a noise index of 25 - 30, VEO retains diagnostic acceptability, as opposed to ASIR and FBP which lose acceptability above noise index of 25. Conclusion: Model-based iterative reconstruction provides superior image quality and anatomical clarity at reduced radiation dosages, supporting the routine use of this technology, particularly in pediatric abdominal CT scans.
推荐文章
Lyocell与Model织物风格比较
再生纤维素纤维
Lyocell织物
Model织物
风格特征
Zircon saturation model in silicate melts: a review and update
Zircon
Zircon saturation
Model
Silicate melt
Mafic to silicic melts
Peraluminous to peralkaline compositions
Igneous rocks
Thermometer
Anti-model测试框架的研究与实现
Anti-model测试
组件
面向方面
测试用例
一体式定位像和分段式定位像配合CARE Dose 4D技术控制PET检查者辐射剂量的比较
定位像
自动管电流调节技术
正电子发射计算机断层显像
计算机断层扫描
剂量长度乘积
CT容积剂量指数
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Comparison of CT Dose Reduction Algorithms in a Porcine Model
来源期刊 计算机断层扫描(英文) 学科 医学
关键词 COMPUTED TOMOGRAPHY DOSE Reduction ITERATIVE Reconstruction PORCINE ASIR VEO FBP
年,卷(期) 2015,(4) 所属期刊栏目
研究方向 页码范围 57-65
页数 9页 分类号 R73
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2015(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
COMPUTED
TOMOGRAPHY
DOSE
Reduction
ITERATIVE
Reconstruction
PORCINE
ASIR
VEO
FBP
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
计算机断层扫描(英文)
季刊
2169-2475
武汉市江夏区汤逊湖北路38号光谷总部空间
出版文献量(篇)
58
总下载数(次)
0
总被引数(次)
0
论文1v1指导