基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
AIM: To compare retinal nerve fiber layer(RNFL) and macular thickness measurements obtained with the Stratus optical coherence tomography(OCT) and OPKO/OTI OCT devices.METHODS: Included in the study were 59 eyes of 30 participants. All measurements for each eye were done on the same day with both devices. Student’s paired t-tests were used to compare the central macular thickness and RNFL measurements of the Stratus OCT and OPKO/OTI OCT. Pearson correlation was used to assess the relationship between the devices. Coefficient of variation(COV) was calculated to assess intersession repeatability.RESULTS: Using both the Stratus OCT and OPKO/OTI OCT, respectively, the measured mean average RNFL thicknesses were 98.9±11.1 μm and 115.1±9.6 μm(P =0.001),and the measured mean central retinal thicknesses(CRT)were 196.2 ±18.8 μm and 204.5 ±21.1 μm(P 【0.001).Measured by the two devices, the RNFL thickness values were correlated in all quadrants, as were the retinal thickness values except the inferior outer sector. COV for average RNFL and CRT thickness were 2.9% and 4.6%for Stratus OCT, and 2.1% and 4.2% for OPKO/OTI OCT,respectively.CONCLUSION: We found good reproducibility of RNFL and retina thickness measurements for both Stratus OCT and OPKO/OTI OCT devices. However, even though the two OCT systems provided statistically correlated results,the values for both RNFL and macular thickness were statistically different. RNFL and macular thickness measurements with the OPKO/OTI OCT were higher than that of the Stratus OCT; therefore, the two OCT systems cannot be used interchangeably for the measurements of RNFL and macular thickness.
推荐文章
用于内窥镜的OCT成像技术
OCT
内窥镜
时域
频域
功能
EDI SD-OCT的眼科应用
频域相干光断层深度增强成像
脉络膜
测量
Stratus OCT在青光眼早期诊断和随访中的应用
光学相干断层扫描
青光眼诊断
视网膜神经纤维层厚度
视盘参数
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Comparison of retinal nerve fiber layer and macular thickness measurements with Stratus OCT and OPKO/OTI OCT devices in healthy subjects
来源期刊 国际眼科杂志:英文版 学科 医学
关键词 OPTICAL COHERENCE TOMOGRAPHY STRATUS OPTICAL COHERENCE TOMOGRAPHY OPKO/OTI OCT retinal nerve fiber layer MACULAR thickness
年,卷(期) 2015,(1) 所属期刊栏目
研究方向 页码范围 98-103
页数 6页 分类号 R770.4
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (29)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2015(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
OPTICAL
COHERENCE
TOMOGRAPHY
STRATUS
OPTICAL
COHERENCE
TOMOGRAPHY
OPKO/OTI
OCT
retinal
nerve
fiber
layer
MACULAR
thickness
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
国际眼科杂志:英文版
月刊
2222-3959
西安市友谊东路269号
出版文献量(篇)
2720
总下载数(次)
2
总被引数(次)
0
论文1v1指导