基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
The main purpose of this research effort was to investigate and reduce the volume of thermal polluted cooling water from returning to the Kafr-Al-Batek power station. Traditional cooling systems, such as cooling towers or ponds can be very challenging with regards to implementation in developing countries;mainly due to the lack of financial capacity. This research focused on low-cost simulation solutions that could improve thermal outcomes. Comparisons were performed between three different scenarios to decrease the elevated temperature of the discharged water (43 °C) released by the Kafr-Al-Batek power station on the Damietta branch. The different scenarios were simulated by using Star CCM+ software. The base scenario examined the discharge angle of an existing outlet. The second scenario examined a new outlet downstream from the existing outlet. The third scenario increased the width of the existing outlet in order to reduce flow velocity. A comparative analysis is provided between the aforementioned solutions to identify the most suitable and cost-effective alternative. Simulation results show that changing the discharge angle from 90° to 135° is the most effective solution. Applying this solution has the potential to decrease the water temperature at the inlet by 7 degrees Celsius (from 32 °C to 25 °C).
推荐文章
Geochemical assessment, mixing behavior and environmental impact of thermal waters in the Guelma geo
Geochemistry
Geothermometry
Mixing
Thermal effluents
Guelma
Algeria
The use of hydrogeochemical analyses and multivariate statistics for the characterization of thermal
Hydrogeochemistry
Thermal waters
Multivariate statistical analysis
Silica geothermometers
Mixing models
Cold groundwaters
Identification of terrigenous and autochthonous organic carbon in sediment cores from cascade reserv
Cascade reservoirs
Terrigenous OC
Lignin
Autochthonous OC
Three-end-member mixing model
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 The Choice of Appropriate Scenario in Order to Reduce the Effect of Thermal Pollution at the Damietta Branch Caused by Cooling Water Discharged from Kafr-Al-Batek Power Station
来源期刊 环境保护(英文) 学科 医学
关键词 Thermal Pollution Short-Circuiting CFD Software Kafr-Al-Batek Power Station Damietta Branch EGYPT
年,卷(期) 2015,(8) 所属期刊栏目
研究方向 页码范围 857-866
页数 10页 分类号 R73
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2015(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
Thermal
Pollution
Short-Circuiting
CFD
Software
Kafr-Al-Batek
Power
Station
Damietta
Branch
EGYPT
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
环境保护(英文)
月刊
2152-2197
武汉市江夏区汤逊湖北路38号光谷总部空间
出版文献量(篇)
956
总下载数(次)
0
总被引数(次)
0
期刊文献
相关文献
推荐文献
论文1v1指导