基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
AIM: To assess lens thickness measurements with anterior segment-optical coherence tomography(AS-OCT)in comparison with A-scan ultrasonography(A-scan US).·METHODS: There were 218 adult subjects(218 eyes)aged 59.2 ±9.2y enrolled in this prospective cross-sectional study. Forty-three eyes had open angles and 175 eyes had narrow angles. Routine ophthalmic exam was performed and nuclear opacity was graded using the Lens Opacities Classification System Ⅲ(LOCS Ⅲ). Lens thickness was measured by AS-OCT(Visante OCT, Carl Zeiss Meditec, Dublin, CA, USA). The highest quality image was selected for each eye and lens thickness was calculated using Image J software. Lens thickness was also measured by A-scan US.·RESULTS: Interclass correlations showed a value of99.7% for intra-visit measurements and 95.3% for inter-visit measurements. The mean lens thickness measured by AS-OCT was not significantly different from that of A-scan US(4.861 ±0.404 vs 4.866 ±0.351 mm, P =0.74).Lens thickness values obtained from the two instruments were highly correlated overall(Pearson correlation coefficient =0.81,P <0.001), and in all LOCS Ⅲ specific subgroups except in grade 5 of nuclear opacity. Bland-Altman analysis revealed a 95% limit of agreement from-0.45 to 0.46 mm. Lens thickness difference between the two instruments became smaller as the lens thickness increased and AS-OCT yielded smaller values than A-scan US in thicker lens(β=-0.29, P <0.001)· CONCLUSION: AS-OCT-derived lens thickness measurement is valid and comparable to the results obtained by A-scan US. It can be used as a reliable noncontact method for measuring lens thickness in adults with or without significant cataract.
推荐文章
智能扫描仪I-Scan校准方法研究
激光跟踪仪
智能扫描仪I-Scan
校准
不确定度
SCAN 3000系统在单质起爆药生产的应用
控制系统
集散控制系统
SCAN3000
单质起爆药生产
应用
Segment Storage System:基于P2P的网络存储服务
网络存储系统
对等网络
分布式哈希表
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Lens thickness assessment : anterior segment optical coherence tomography versus A-scan ultrasonography
来源期刊 国际眼科杂志:英文版 学科 医学
关键词 透镜厚度 A 扫描 ultrasonography 前面的片断光的连贯断层摄影术 寿命测定 奔流
年,卷(期) 2015,(6) 所属期刊栏目
研究方向 页码范围 1151-1155
页数 0页 分类号 R776.1
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2015(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
透镜厚度
A
扫描
ultrasonography
前面的片断光的连贯断层摄影术
寿命测定
奔流
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
国际眼科杂志:英文版
月刊
2222-3959
西安市友谊东路269号
出版文献量(篇)
2720
总下载数(次)
2
总被引数(次)
0
论文1v1指导