基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
There is considerable disparity in the published apparent diffusion coefficient(ADC) values across different anatomies. Institutions are increasingly assessing repeatability and reproducibility of the derived ADC to determine its variation,which could potentially be used as an indicator in determining tumour aggressiveness or assessing tumour response. In this manuscript,a review of selected articles published to date in healthy extracranial body diffusion-weighted magnetic resonance imaging is presented,detailing reported ADC values and discussing their variation across different studies. In total 115 studies were selected including 28 for liver parenchyma,15 for kidney(renal parenchyma),14 for spleen,13 for pancreatic body,6 for gallbladder,13 for prostate,13 for uterus(endometrium,myometrium,cervix) and 13 for fibroglandular breast tissue. Median ADC values in selected studies were found to be 1.28 × 10-3 mm2/s in liver,1.94 × 10-3 mm2/s in kidney,1.60 × 10-3 mm2/s in pancreatic body,0.85 × 10-3 mm2/s in spleen,2.73 × 10-3 mm2/s in gallbladder,1.64 × 10-3 mm2/s and 1.31 × 10-3 mm2/s in prostate peripheral zone and central gland respectively(combined median value of 1.54×10-3 mm2/s),1.44 × 10-3 mm2/s in endometrium,1.53 × 10-3 mm2/s in myometrium,1.71 × 10-3 mm2/s in cervix and 1.92 × 10-3 mm2/s in breast. In addition,six phantom studies and thirteen in vivo studies were summarized to compare repeatability and reproducibility of the measured ADC. All selected phantom studies demonstrated lower intra-scanner and inter-scanner variation compared to in vivo studies. Based on the findings of this manuscript,it is recommended that protocols need to be optimised for the body part studied and that system-induced variability must be established using a standardized phantom in any clinical study. Reproducibility of the measured ADC must also be assessed in a volunteer population,as variations are far more significant in vivo compared with phantom studies.
推荐文章
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Diffusion-weighted magnetic resonance imaging in cancer:Reported apparent diffusion coefficients,in-vitro and invivo reproducibility
来源期刊 世界放射学杂志:英文版(电子版) 学科 医学
关键词 Diffusion-weighted magnetic resonance IMAGING APPARENT DIFFUSION COEFFICIENT REPRODUCIBILITY APPARENT DIFFUSION COEFFICIENT CANCER IMAGING Extracranial organs
年,卷(期) 2016,(1) 所属期刊栏目
研究方向 页码范围 21-49
页数 29页 分类号 R730.4
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2016(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
Diffusion-weighted
magnetic
resonance
IMAGING
APPARENT
DIFFUSION
COEFFICIENT
REPRODUCIBILITY
APPARENT
DIFFUSION
COEFFICIENT
CANCER
IMAGING
Extracranial
organs
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
世界放射学杂志:英文版(电子版)
月刊
1949-8470
北京市朝阳区东四环中路62号楼远洋国际中
出版文献量(篇)
785
总下载数(次)
1
总被引数(次)
0
论文1v1指导