摘要:
AIM: To study the leakage-penumbra(LP) effect with a proposed correction method for the step-and-shoot intensity modulated radiation therapy(IMRT).METHODS: Leakage-penumbra dose profiles from 10 randomly selected prostate IMRT plans were studied. The IMRT plans were delivered by a Varian 21 EX linear accelerator equipped with a 120-leaf multileaf collimator(MLC). For each treatment plan created by the Pinnacle3 treatment planning system,a 3-dimensional LP dose distribution generated by 5 coplanar photon beams,starting from 0o with equal separation of 72 o,was investigated. For each photon beam used in the stepand-shoot IMRT plans,the first beam segment was set to have the largest area in the MLC leaf-sequencing,and was equal to the planning target volume(PTV). The overshoot effect(OSE) and the segment positional errors were measured using a solid water phantom with Kodak(TL and X-OMAT V) radiographic films. Film dosimetric analysis and calibration were carried out using a film scanner(Vidar VXR-16). The LP dose profiles were determined by eliminating the OSE and segment positional errors with specific individual irradiations. RESULTS: A non-uniformly distributed leaf LP dose ranging from 3% to 5% of the beam dose was measured in clinical IMRT beams. An overdose at the gap between neighboring segments,represented as dose peaks of up to 10% of the total BP,was measured. The LP effect increased the dose to the PTV and surrounding critical tissues. In addition,the effectdepends on the number of beams and segments for each beam. Segment positional error was less than the maximum tolerance of 1 mm under a dose rate of 600 monitor units per minute in the treatment plans. The OSE varying with the dose rate was observed in all photon beams,and the effect increased from 1 to 1.3 Gy per treatment of the rectal intersection. As the dosimetric impacts from the LP effect and OSE may increase the rectal post-radiation effects,a correction of LP was proposed and demonstrated for the central beam profile for one of the planned be
推荐文章
RS码改进的step-by-step译码算法
RS码
step-by-step
译码算法
伴随式矩阵
Ecosystem service delivery in Karst landscapes: anthropogenic perturbation and recovery
Soil degradation
Ecosystem services
Caesium-137
Karst, China
基于GPU实现SlideShow中的effect和transition
图像处理器
Direct3D
SlideShow
固定功能流水线
可编程流水线
高级渲染语言
顶点渲染
像素渲染
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Leakage-Penumbra effect in intensity modulated radiation therapy step-and-shoot dose delivery
来源期刊 世界放射学杂志:英文版(电子版) 学科 医学
关键词 Multileaf COLLIMATOR LEAKAGE OVERSHOOT EFFECT Beam PENUMBRA PROSTATE intensity modulated radiation therapy planning
年,卷(期) 2016,(1) 所属期刊栏目
研究方向 页码范围 73-81
页数 9页 分类号 R730.55
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2016(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
Multileaf
COLLIMATOR
LEAKAGE
OVERSHOOT
EFFECT
Beam
PENUMBRA
PROSTATE
intensity
modulated
radiation
therapy
planning
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
世界放射学杂志:英文版(电子版)
月刊
1949-8470
北京市朝阳区东四环中路62号楼远洋国际中
出版文献量(篇)
785
总下载数(次)
1
总被引数(次)
0
论文1v1指导