基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
AIM: To use magnetic resonance-guided high intensity focused ultrasound(MRg-HIFU), magnetic resonance imaging(MRI) and histopathology for noninvasively ablating, quantifying and characterizing ablated renal tissue. METHODS: Six anesthetized/mechanically-ventilated pigs underwent single/double renal sonication(n = 24) using a 3T-MRg-HIFU(1.1 MHz frequency and 3000J-4400 J energies). T2-weighted fast spin echo(T2-W), perfusion saturation recovery gradient echo and contrast enhanced(CE) T1-weighted(T1-W) sequences were used for treatment planning, temperature monitoring, lesion visualization, characterization and quantification, respectively. Histopathology was conducted in excised kidneys to quantify and characterize cellular and vascular changes. Paired Student’s t-test was used and a P-value < 0.05 was considered statistically significant.RESULTS: Ablated renal parenchyma could not be differentiated from normal parenchyma on T2-W or nonCE T1-W sequences. Ablated renal lesions were visible as hypoenhanced regions on perfusion and CE T1-W MRI sequences, suggesting perfusion deficits and necrosis. Volumes of ablated parenchyma on CE T1-W images invivo(0.12-0.36 cm3 for single sonication 3000 J, 0.50-0.84 cm3, for double 3000 J, 0.75-0.78 cm3 for single 4400 J and 0.12-2.65 cm3 for double 4400J) and at postmortem(0.23-0.52 cm3, 0.25-0.82 cm3, 0.45-0.68 cm3 and 0.29-1.80 cm3, respectively) were comparable. The ablated volumes on 3000 J and 4400 J double sonication were significantly larger than single(P < 0.01), thus, the volume and depth of ablated tissue depends on the applied energy and number of sonication. Macroscopic and microscopic examinations confirmed the locations and presence of coagulation necrosis, vascular damage and interstitial hemorrhage, respectively.CONCLUSION: Contrast enhanced MRI provides assessment of MRg-HIFU renal ablation. Histopathology demonstrated coagulation necrosis, vascular damage and confirmed the volume of damage seen on MRI.
推荐文章
Magnetic Influences of Cement Dust on Soil in Industrial Area and Its Environmental Implications
Cement dust
Soil
Magnetic property
Environmental significance
A re-assessment of nickel-doping method in iron isotope analysis on rock samples using multi-collect
Fe isotope
Ni-doping
Stable isotope
Precision and accuracy
Mass bias correction
Pseudo-high mass resolution
Groundwater quality assessment using multivariate analysis, geostatistical modeling, and water quali
Groundwater
Multivariate analysis
Geostatistical modeling
Geochemical modeling
Mineralization
Ordinary Kriging
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Renal ablation using magnetic resonance-guided high intensity focused ultrasound: Magnetic resonance imaging and histopathology assessment
来源期刊 世界放射学杂志:英文版(电子版) 学科 医学
关键词 Magnetic resonance-guided high INTENSITY FOCUSED ULTRASOUND RENAL ablation Magnetic RESONANCE imaging Microscopy High INTENSITY FOCUSED ULTRASOUND
年,卷(期) 2016,(3) 所属期刊栏目
研究方向 页码范围 298-307
页数 10页 分类号 R445
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2016(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
Magnetic
resonance-guided
high
INTENSITY
FOCUSED
ULTRASOUND
RENAL
ablation
Magnetic
RESONANCE
imaging
Microscopy
High
INTENSITY
FOCUSED
ULTRASOUND
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
世界放射学杂志:英文版(电子版)
月刊
1949-8470
北京市朝阳区东四环中路62号楼远洋国际中
出版文献量(篇)
785
总下载数(次)
1
总被引数(次)
0
论文1v1指导