基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
Purpose: Both physical and virtual wedges are used in radiotherapy to get uniform and desired dose distribution in clinical setting. All linear accelerators of different venders have computer controlled dynamic wedges called virtual wedge filters. Penumbra is one of the important photon beam characteristics needed to be understood in radiation therapy at the time of commissioning of Treatment Planning system (TPS) as well as applying various treatment planning algorithms in clinical applications. In this study we measured the dose profiles of open field, physical wedges (PW) and virtual wedges (VW) for energies (6 MV & 15 MV), various field sizes (10 × 10, 15 × 15 & 20 × 20 cm2), depths (dmax, 10 cm, 20 cm) and wedge angles (15°, 30°, 45° and 60°). From beam profile we calculated the penumbral width for open and wedged fields. The study was carried out on Siemens ONCOR IMRT Plus linear accelerator. The obtained penumbral width of PW and VW of all wedge angles was subtracted from the penumbral width of open field. The deviations in penumbral width were compared and statistically analyzed as a function of energy, depth, field size and wedge angles. Material and Method: The penumbral width was measured using IBA CC13 ion chamber in IBA Blue phantom (a 3D water phantom). The source to surface distance (SSD) during our study was kept 100cm and measurement was taken for 10 × 10, 15 × 15, 20 × 20 cm2 field sizes and for 15°, 30°, 45°, 60° wedges. These measurements were taken for both 6 MV and 15 MV photon energies. Virtual wedge profiles were acquired using LDA-99 linear detector array (IBA, Germany). The deviations in penumbral width for both PW and VW were calculated by subtracting the penumbral width from open field penumbral width in gun direction (in-plane) and deviation in VW penumbral width, and were obtained by subtracting the open field penumbral width in left-right direction (cross-plane) direction. The measured deviations were plotted for both PW and VW. Statistics on the measured deviations wa
推荐文章
Behavior of rare earth elements in granitic profiles, eastern Tibetan Plateau, China
Chemical weathering
Eu anomaly
Critical zone
Soil weathering
平行四边法则在Omni-Wedge刻度中的应用
平行四边形法
Omni-Wedge
刻度
有效性
Hydrodynamic characteristics of Wujiangdu Reservoir during the dry season—a case study of a canyon r
Canyon reservoir
Hydrodynamic characteristics
A transition zone
Wujiang River
利用集群技术构建Linux Virtual Server
集群
负载均衡
Virtual
Server
地址转换
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Penumbral Dose Characteristics of Physical and Virtual Wedge Profiles
来源期刊 医学物理学、临床工程、放射肿瘤学(英文) 学科 医学
关键词 PHYSICAL WEDGE VIRTUAL WEDGE PENUMBRA and DEVIATIONS
年,卷(期) 2017,(2) 所属期刊栏目
研究方向 页码范围 216-224
页数 9页 分类号 R73
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2017(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
PHYSICAL
WEDGE
VIRTUAL
WEDGE
PENUMBRA
and
DEVIATIONS
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
医学物理学、临床工程、放射肿瘤学(英文)
季刊
2168-5436
武汉市江夏区汤逊湖北路38号光谷总部空间
出版文献量(篇)
236
总下载数(次)
0
总被引数(次)
0
论文1v1指导