基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
Background Transvenous lead placement is the standard approach for left ventricular (LV) pacing in cardiac resynchronization therapy (CRT),while the open chest access epicardial lead placement is currently the most frequently used second choice.Our study aimed to compare the ventricular electromechanical synchronicity in patients with heart failure after CRT with these two different LV pacing techniques.Methods We enrolled 33 consecutive patients with refractory heart failure secondly to dilated cardiomyopathy who were eligible for CRT in this study.Nineteen patients received transvenous (TV group) while 14 received open chest (OP group) LV lead pacing.Intraand inter-ventricular electromechanical synchronicity was assessed by tissue Doppler imaging (TDI) before and one year after CRT procedure.Results Before CRT procedure,the mean QRS-duration,maximum time difference to systolic peak velocity among 12 left ventricle segments (LV Ts-12),standard deviation of time difference to systolic peak velocity of 12 left ventricle segments (LV Ts-SD),and inter-ventricular mechanical delay (IVMD) in OP and TV group were 166 ± 17 ms and 170 ± 21 ms,391 ± 42 ms and 397 ± 36 ms,144 ± 30 ms and 148 ± 22 ms,58 ± 25 ms and 60 ± 36 ms,respectively (all P > 0.05).At one year after the CRT,the mean QRS-duration,LV Ts-12,LV Ts-SD,and IVMD in TV and OP group were 128 ± 14 ms and 141 ± 22 ms (P =0.031),136 ± 37 ms and 294 ± 119 ms (P =0.023),50 ± 22 ms and 96 ± 34 ms (P =0.015),27 ± 11 ms and 27 ± 26 ms (P =0.86),respectively.The LV lead implantation procedure time was 53.4 ± 16.3 min for OP group and 136 ± 35.1 min for TV group (P =0.016).The mean LV pacing threshold increased significantly from 1.7 ± 0.6 V/0.5 ms to 2.3 ± 1.6 V/0.5 ms (P < 0.05) in TV group while it remained stable in the OP group.Conclusions Compared to conventional endovascular approach,open chest access of LV pacing for CRT leads to better improvement of the intraventricular synchronization.
推荐文章
期刊_丙丁烷TDLAS测量系统的吸收峰自动检测
带间级联激光器
调谐半导体激光吸收光谱
雾剂检漏 中红外吸收峰 洛伦兹光谱线型
期刊_联合空间信息的改进低秩稀疏矩阵分解的高光谱异常目标检测
高光谱图像
异常目标检测 低秩稀疏矩阵分解 稀疏矩阵 残差矩阵
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Transvenous versus open chest lead placement for resynchronization therapy in patients with heart failure: comparison of ventricular electromechanical synchronicity
来源期刊 老年心脏病学杂志(英文版) 学科
关键词
年,卷(期) 2017,(4) 所属期刊栏目
研究方向 页码范围 261-265
页数 5页 分类号
字数 语种 英文
DOI 10.11909/j.issn.1671-5411.2017.04.001
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (11)
共引文献  (16)
参考文献  (13)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2001(1)
  • 参考文献(1)
  • 二级参考文献(0)
2002(2)
  • 参考文献(2)
  • 二级参考文献(0)
2003(2)
  • 参考文献(2)
  • 二级参考文献(0)
2004(2)
  • 参考文献(2)
  • 二级参考文献(0)
2008(2)
  • 参考文献(1)
  • 二级参考文献(1)
2011(2)
  • 参考文献(1)
  • 二级参考文献(1)
2012(1)
  • 参考文献(0)
  • 二级参考文献(1)
2013(3)
  • 参考文献(2)
  • 二级参考文献(1)
2014(4)
  • 参考文献(1)
  • 二级参考文献(3)
2015(4)
  • 参考文献(0)
  • 二级参考文献(4)
2017(1)
  • 参考文献(1)
  • 二级参考文献(0)
2017(1)
  • 参考文献(1)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
引文网络交叉学科
相关学者/机构
期刊影响力
老年心脏病学杂志(英文版)
月刊
1671-5411
11-5329/R
16开
北京市复兴路28号老年心脏病学杂志(英文版)编辑部
2004
eng
出版文献量(篇)
1086
总下载数(次)
0
总被引数(次)
2028
论文1v1指导