基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
Complications and shortcomings of volar plating, which is very widely used for surgical treatment of distal radius fractures, are well known. Thus, there is scope for alternative innovative surgical methods. In the present work, we used the finite element analysis method to compare the biomechanical performance of a model of a construct comprising a simulated distal radius fracture considered fixated using a notional intramedullary injectable bioresorbable polymer-bioresorbable balloon osteosynthesis system (“fixator”) versus using a commercially-available volar locking plate (VP). The biomechanical parameters determined were longitudinal stiffness and factor of safety under each of the applied loads.?For the fixator model, 1) each of the biomechanical parameters was markedly influenced by fracture gap fill ratio (FGFR) (defined as the proportion of the volume of the fracture gap that is considered occupied by the expanded polymer-filled balloon)?but not by modulus of elasticity assigned to the polymer;2) with FGFR = 100%, stiffness was comparable to that of the Ti-6Al-4V alloy VP construct model;and 3) stiffness was within the range of literature values for stiffness of constructs comprising simulated fractures in fresh cadaveric distal radii fixated using metal volar locking plate. These results suggest that the fixator may be an alternative modality to metal volar plating and, as such, deserves further evaluation.
推荐文章
Using Geomechanical Method to Predict Tectonic Fractures in Low-Permeability Sandstone Reservoirs
Low-permeability sandstone reservoir
Fracture parameters
Geomechanical method
Prospectivity modeling of porphyry copper deposits: recognition of efficient mono- and multi-element
Geochemical signature
Concentration–area (C–A) fractal
Principal component analysis (PCA)
Student's t-value
Fuzzy mineral prospectivity modeling(MPM)
Prediction–area (P–A) plot
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Finite Element Analysis Study of Prototype of a Novel Intramedullary Injectable Bioresorbable Polymer Fixator versus a Volar Plate for Surgical Treatment of Distal Radius Fractures
来源期刊 世界工程和技术(英文) 学科 医学
关键词 DISTAL Radius Fracture VOLAR Locking Plate INTRAMEDULLARY Fixation Finite Element Analysis
年,卷(期) 2017,(4) 所属期刊栏目
研究方向 页码范围 648-667
页数 20页 分类号 R6
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2017(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
DISTAL
Radius
Fracture
VOLAR
Locking
Plate
INTRAMEDULLARY
Fixation
Finite
Element
Analysis
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
世界工程和技术(英文)
季刊
2331-4222
武汉市江夏区汤逊湖北路38号光谷总部空间
出版文献量(篇)
482
总下载数(次)
0
论文1v1指导