基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
AIM:To determine the effects of peripheral corneal thickness(PCT) on dynamic contour tonometry(DCT) and Goldmann applanation tonometry(GAT).METHODS:A cross-sectional study.We created a software which calculates the corneal contour(CC) as a function of the radius from the corneal apex to each pixel of the contour.The software generates a central circumference with a radius of 1 mm and the remainder of the cornea is segmented in 5 rings concentric with corneal apex being its diameter not constant around the corneal circumference as a consequence of the irregular CC but keeping constant the diameter of each ring in each direction of the contour.PCT was determined as the mean thickness of the most eccentric ring.Locally weighted scatterplot smoothing(LOWESS) regression was used to determine the pattern of the relationship between PCT and both DCT and GAT respectively.Thereafter,two multivariable linear regression models were constructed.In each of them,the dependant variable was intraocular pressure(IOP) as determined using GAT and DCT respectively.In both of the models the predictive variable was PCT though LOWESS regression pattern was used to model the relationship between the dependant variables and the predictor one.Age and sex were also introduced control variables along with their first-degree interactions with PCT.Main outcome measures include amount of IOP variation explained through regression models(R2) and regression coefficients(B).RESULTS:Subjects included 109 eyes of 109 healthy individuals.LOWESS regression suggested that a 2 nd-degree polynomial would be suitable to model the relationship between both DCT and GAT with PCT.Hence PCT was introduced in both models as a linear and quadratic term.Neither age nor sex nor interactions were statistically significant in both models.For GAT model,R2 was 17.14%(F=9.02;P=0.0002),PCT linear term B was-1.163(95% CI:-1.163,-0.617).PCT quadratic term B was 0.00081(95% CI:0.00043,0.00118).For DCT model R2 was 14.28%(F=9.29;P=0.0002),PCT linear term B was-0.712(95% CI
推荐文章
凯途(CONTOUR)在低位直肠癌双吻合器技术中的应用
直肠肿瘤
双吻合器技术
凯途(CONTOUR)
Contour-Ⅱ型乳腺钼靶X光机软故障一例
钼靶X光机
压迫器
软故障
A Discussion on Dynamic Characteristics of Undisturbed Loess by Dynamic Triaxial Test
三轴试验系统
原状黄土
动态特性
随机地震荷载
振动模式
比较试验
应变曲线
正弦波
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Dependence of dynamic contour and Goldmann applanation tonometries on peripheral corneal thickness
来源期刊 国际眼科杂志:英文版 学科 医学
关键词
年,卷(期) gjykzzywb_2017,(10) 所属期刊栏目
研究方向 页码范围 1521-1527
页数 7页 分类号 R77
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2017(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
引文网络交叉学科
相关学者/机构
期刊影响力
国际眼科杂志:英文版
月刊
2222-3959
西安市友谊东路269号
出版文献量(篇)
2720
总下载数(次)
2
论文1v1指导