摘要:
Purpose: With usually a millimeter-level PTV margin, stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT) pose a stringent requirement on the isocentricity of the Linac. This requirement is partly fulfilled by routine isocenter quality assurance (QA) test to verify the size and location of the isocenter. The current common QA methods such as spoke shot were developed before SBRT/SRS became popular and when IGRT was largely absent and hence have their limitations. In this work, we describe an isocenter QA approach based on portal imaging to provide the community with a superior alternative. Methods: The proposed approach utilizes a BrainLab ball bearing (BB) phantom in conjunction with an electronic portal imaging devices (EPID) imager. The BB phantom was first aligned with a calibrated room laser system. Portal images were then acquired using 6 MV beam with a 2 × 2 cm2 open field and a 15 mm cone on a Varian TrueBeam STx machine. The gantry, collimator, and table were rotated separately at selected angles to acquire a series of portal images in order to determine the isocenter of each rotating system. The location and diameter of these isocenters were determined by calculating the relative displacement of either BB or open field edge between the acquired EPID images. The demonstration of the reproducibility and robustness of this EPID-based approach was carried out by repeating measurements 10 times independently for each rotating system and simulating clinical scenarios of asymmetric jaws and misalignment of BB phantom, respectively. Results: For our TrueBeam STx machine, the isocenter diameter derived from open-field EPID images was roughly 0.15 mm, 0.18 mm, 0.49 mm for the collimator, table, and gantry, respectively. For the collimator and gantry, images taken with the cone gave considerably smaller isocenter diameter. Results remained almost unchanged despite the presence of simulated BB misalignment and asymmetric jaws error, and between independent measurements. Isocenter location
推荐文章
计算网格Portal的设计与实现
网格计算
网格门户
Portal
Globus
Web/Portal认证技术研究
Web/Portal认证
强制认证
ARP/心跳报文断线检测
二次DHCP地址分配
Limestone mechanical deformation behavior and failure mechanisms: a review
Mechanical deformation
Brittle fracture
Ductility failure
Strength criterion
基于GridSphere面向服务的网格Portal研究与设计
网格门户
网格服务
Web服务
GridSphere
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 A Quality Assurance Approach for Linear Accelerator Mechanical Isocenters with Portal Images
来源期刊 医学物理学、临床工程、放射肿瘤学(英文) 学科 医学
关键词 Linear ACCELERATOR ISOCENTER MECHANICAL Check Quality ASSURANCE SPOKE Shot
年,卷(期) 2018,(1) 所属期刊栏目
研究方向 页码范围 100-114
页数 15页 分类号 R73
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2018(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
Linear
ACCELERATOR
ISOCENTER
MECHANICAL
Check
Quality
ASSURANCE
SPOKE
Shot
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
医学物理学、临床工程、放射肿瘤学(英文)
季刊
2168-5436
武汉市江夏区汤逊湖北路38号光谷总部空间
出版文献量(篇)
236
总下载数(次)
0
总被引数(次)
0
论文1v1指导