基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
Tissue-classification-based attenuation correction strategies have been previously proposed to correct for bone attenuation in PET/MR imaging and simulated using computed tomography. However, the complication of voxel averaging uniquely associated with bone has not been considered explicitly in the past. This study investigated the effect of voxel averaging between bone and soft tissue in attenuation images and determined how accurately bone must be detected in MR images in order to perform acceptable attenuation correction of PET data by using CT-simulated attenuation correction. We found out that treating bone as soft tissue caused a mean quantification difference of -9.9% ± 5.5% in all 119 bone lesions. There were no significant differences between lesions in the pelvis and the vertebrae. The nominal difference in lesions in the ribs was significantly lower, likely due to the spatial misregistration between the emission and attenuation images. Interestingly, a non-monotonic relationship between the bone imaging ability and the absolute PET quantification accuracy was observed, with the minimal quantification difference achieved at a BVF around 40% for skull lesions (2.6% ± 2.1%), and 30% for non-skull lesions (1.4% ± 1.1%) and all lesions (1.5% ± 1.3%). This study established that a bone classification sensitivity of approximately 30% BVF is required in order for MR-based attenuation correction methods to achieve optimal quantification in whole-body PET/MR studies. For this purpose, higher bone imaging ability of MR may not be necessary.
推荐文章
PET/CT与PET/MR诊断恶性肿瘤的临床对照研究
肿瘤,各部位
正电子发射断层显像术
体层摄影术,螺旋计算机
磁共振成像
多示踪剂PET/PET-CT 显像在肺癌诊断中的价值
正电子发射断层显像
肺癌
氟代脱氧葡萄糖
示踪剂
联合18F-FDG和18F-NaF PET/CT对骶骨衰竭性骨折及转移瘤的鉴别诊断价值
骶骨
衰竭性骨折
转移瘤
正电子发射体层成像
氟代脱氧葡萄糖
氟化钠
最大标准摄取值
PET/MR场所选址与布局设计
正电子发射型磁共振成像系统
场所选址
布局设计
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 An Investigation of the Required MR Bone Attenuation Correction for Quantitative Whole-Body PET/MR Imaging Using Clinical NaF PET/CT Studies
来源期刊 医学物理学、临床工程、放射肿瘤学(英文) 学科 医学
关键词 PET/MR ATTENUATION CORRECTION MR-Based ATTENUATION CORRECTION
年,卷(期) 2018,(3) 所属期刊栏目
研究方向 页码范围 273-295
页数 23页 分类号 R73
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2018(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
PET/MR
ATTENUATION
CORRECTION
MR-Based
ATTENUATION
CORRECTION
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
医学物理学、临床工程、放射肿瘤学(英文)
季刊
2168-5436
武汉市江夏区汤逊湖北路38号光谷总部空间
出版文献量(篇)
236
总下载数(次)
0
总被引数(次)
0
论文1v1指导