Delivered by intramuscular (IM) injections, Long Acting Injections (LAI), offering comparatively long term medicinal effects from several weeks to several months, are gaining much attention. The aim of this article was to indicate a safe and effective IM injection technique based on evidenced data derived from ultrasonographic data. Accurate anatomical knowledge is necessary in order to administer IM injections. It is possible to gain an adequate understanding of injection site anatomical structures by using ultrasound diagnostic devices. In particular, ultrasonography offers real-time diagnostic data allowing for observation of injection site, subcutaneous tissues, fat layers, muscle membrane, muscles and bones. To deliver the drug accurately into the muscle is essential, to achieve maximum drug efficacy and prevent injection site reactions. Therefore, when administering IM injections to the buttocks area, a suitable injection needle between 23G 25 mm to 21G or 22G 38 mm must be chosen depending on physique and drug characteristics. Needles determined as safe and effective through ultrasonographic evidence are needed such as in the case of a deltoid injection site, in which a 23G 25 mm injection needle is used in the absence of notable obesity. Not only the needle type is essential, but also the IM procedure itself. It is important to stretch the skin, inserting the needle at 90 degree angle to ensure depth of needle insertion to the muscle. Until new con-firmed evidence becomes available, it is necessary to increase the understanding of injection site selection methods, needle insertion depth, needle angle, and established IM injection techniques. The application of ultrasound devices in the development of next-generation techniques for IM injection is promising. Importantly, these techniques provide critical information from a risk management perspective.
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Efficacy and Safety in Intramuscular Injection Techniques Using Ultrasonographic Data
来源期刊 健康(英文) 学科 医学
关键词 INTRAMUSCULAR INJECTION Long ACTING INJECTABLE INJECTION Site Reaction ULTRASOUND DIAGNOSTIC Device INTRAMUSCULAR INJECTION Technique
年,卷(期) 2018,(3) 所属期刊栏目
研究方向 页码范围 334-350
页数 17页 分类号 R73
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2018(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
INTRAMUSCULAR
INJECTION
Long
ACTING
INJECTABLE
INJECTION
Site
Reaction
ULTRASOUND
DIAGNOSTIC
Device
INTRAMUSCULAR
INJECTION
Technique
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
健康(英文)
月刊
1949-4998
武汉市江夏区汤逊湖北路38号光谷总部空间
出版文献量(篇)
328
总下载数(次)
0
总被引数(次)
0
论文1v1指导