基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
AIM To analyze how various implants placement variables affect sacroiliac(SI)joint range of motion.METHODS An experimentally validated finite element model of the lumbar spine and pelvis was used to simulate a fusion of the SI joint using various placement configurations of triangular implants(iFuse Implant System?).Placement configurations were varied by changing implant orientation,superior implant length,and number of implants.The range of motion of the SI joint was calculated using a constant moment of 10 N-m with a follower load of 400 N.The changes in motion were compared between the treatment groups to assess how the different variables affected the overall motion of the SI joint.RESULTS Transarticular placement of 3 implants with superior implants that end in the middle of the sacrum resulted in the greatest reduction in range of motion(flexion/extension=73%,lateral bending=42%,axial rotation=72%).The range of motions of the SI joints were reduced with use of transarticular orientation(9%-18%)when compared with an inline orientation.The use of a superior implant that ended mid-sacrum resulted in median reductions of(8%-14%)when compared with a superior implant that ended in the middle of the ala.Reducing the number of implants,resulted in increased SI joint range of motions for the 1 and 2 implant models of 29%-133%and 2%-39%,respectively,when compared with the 3 implant model.CONCLUSION Using a validated finite element model we demonstrated that placement of 3 implants across the SI joint using a transarticular orientation with superior implant reaching the sacral midline resulted in the most stable construct.Additional clinical studies may be required to confirm these results.
推荐文章
Prospectivity modeling of porphyry copper deposits: recognition of efficient mono- and multi-element
Geochemical signature
Concentration–area (C–A) fractal
Principal component analysis (PCA)
Student's t-value
Fuzzy mineral prospectivity modeling(MPM)
Prediction–area (P–A) plot
A re-assessment of nickel-doping method in iron isotope analysis on rock samples using multi-collect
Fe isotope
Ni-doping
Stable isotope
Precision and accuracy
Mass bias correction
Pseudo-high mass resolution
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Sacroiliac joint stability:Finite element analysis of implant number,orientation,and superior implant length
来源期刊 世界骨科杂志 学科 医学
关键词 Fusion BIOMECHANICS MINIMALLY invasive surgery SACROILIAC joint DYSFUNCTION Finite element analysis
年,卷(期) 2018,(3) 所属期刊栏目
研究方向 页码范围 14-23
页数 10页 分类号 R
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2018(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
Fusion
BIOMECHANICS
MINIMALLY
invasive
surgery
SACROILIAC
joint
DYSFUNCTION
Finite
element
analysis
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
世界骨科杂志:英文版
月刊
2218-5836
北京市朝阳区东四环中路62号楼远洋国际中
出版文献量(篇)
404
总下载数(次)
1
总被引数(次)
0
期刊文献
相关文献
推荐文献
论文1v1指导