基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
In the first part of this investigation, a Natural Gas Combined Cycle (NGCC) producing 620 MW of electricity was simulated using the commercial software Aspen Hysys V9.0 and the Soave-Redlich-Kwong (SRK) equation of state. The aim of this second part is to use exergy-based analyses in order to calculate its exergy efficiency and evaluate its environmental impact under standard conditions. For the exergy efficiency, the performance index under investigation is the exergy destruction ratio (yD). The results of the study show that the combustor is the main contributor to the total exergy destruction of the power plant (yD = 24.35%) and has the lowest exergy efficiency of 75.65%. On the other hand, the Heat Recovery Steam Generator (HRSG) has the lowest contribution to the exergy destruction (yD = 5.63%) of the power plant and the highest exergy efficiency of 94.37%. For the overall power plant, the exergy efficiency is equal to 53.28%. For the environmental impact of the power plant, the relative difference of exergy-related environmental impacts (rb) is utilized as the performance index for each equipment of the plant and the environmental impact of a kWh of electricity (EIE) is used to represent the performance index of the overall power plant. In agreement with the exergy analysis, the results indicate that the combustor and the HRSG have respectively the highest (rb = 32.19%) and the lowest (rb = 5.96%) contribution to the environmental impact. The environmental impact of a kWh of electricity of the power plant is 34.26 mPts/kWh (exergy destruction only), and 34.42 mPts/kWh (both exergy destruction and exergy loss).
推荐文章
A combined IR and XRD study of natural well crystalline goethites(α-FeOOH)
Crystallinity
Goethite
IR-spectrometry
X-ray diffraction
XRD rietveld refinement
Characterization
Geochemical assessment, mixing behavior and environmental impact of thermal waters in the Guelma geo
Geochemistry
Geothermometry
Mixing
Thermal effluents
Guelma
Algeria
高温气冷堆氦气透平直接循环的Exergy分析
热力学分析
Exergy分析
高温气冷堆
布雷登循环
Exergy损失
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Exergy Efficiency and Environmental Impact of Electricity of a 620 MW-Natural Gas Combined Cycle
来源期刊 电力能源(英文) 学科 医学
关键词 EXERGY Analysis NGCC Power Plant Life Cycle IMPACT Assessment (LCIA) Method Environmental IMPACT of ELECTRICITY
年,卷(期) dlnyyw_2018,(7) 所属期刊栏目
研究方向 页码范围 1-21
页数 21页 分类号 R73
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2018(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
EXERGY
Analysis
NGCC
Power
Plant
Life
Cycle
IMPACT
Assessment
(LCIA)
Method
Environmental
IMPACT
of
ELECTRICITY
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
电力能源(英文)
月刊
2327-588X
武汉市江夏区汤逊湖北路38号光谷总部空间
出版文献量(篇)
568
总下载数(次)
0
论文1v1指导