摘要:
Background Percutaneous coronary intervention (PCI) had become the major therapeutic procedure for coronary artery disease (CAD),but the high rate of in-stent restenosis (ISR) still remained an unsolved clinical problem in clinical practice.Increasing evidences suggested that diabetes mellitus (DM) was a major risk factor for ISR,but the risk predictors ofISR in CAD patients with DM had not been well characterized.The aim of this study was to investigate the clinical and angiographic characteristic predictors significantly associated with the occurrence of ISR in diabetic patients following coronary stenting with drug-eluting stent (DES).Methods A total of 920 patients with diabetes who diagnosed CAD and underwent coronary DES implantation at Beijing Anzhen Hospital in China were consecutively enrolled from January 2012 to December 2012.Of these,440 patients underwent the second angiography within ≥ 6 months due to the progression of treated target lesions.Finally,368 of these patients who met the inclusion and exclusion criteria were followed up by angiography after baseline PCI.According to whether ISR was detected at follow-up angiography,patients were divided into the ISR group (n =74) and the non-ISR group (n =294).The independent predictors of ISR in patients with DM were explored by multivariate Cox's proportional hazards regression models.Results A total of 368 patients (260 women and 108 men) with a mean ages of 58.71 ± 10.25 years were finally enrolled in this study.Of these,ISR occurred in 74/368 diabetic patients (20.11%) by follow-up angiography.Univariate analysis showed that most baseline characteristics of the ISR and non-ISR group were similar.Patients in the ISR group had significantly higher serum very low density lipoprotein cholesterol (VLDL-C),triglyceride (TG) and uric acid (UA) levels,more numbers of target vessel lesions,higher prevalence of multi-vessel disease,higher SYNTAX score,higher rate of previous but lower rate of drinking compared with patients in the non-ISR group.The independent predictors of ISR in patients with DM after DES implantation included VLDL-C (HR =1.85,95% CI:1.24-2.77,P =0.002),UA (per 50 μmol/L increments,HR =1.19,95% CI:1.05-1.34,P =0.006),SYNTAX score (per 5 increments,HR =1.34,95% CI:1.03-1.74,P =0.031) and the history ofPCI (HR =3.43,95% CI:1.57-7.80,P =0.003) by the multivariate Cox's proportional hazards regression analysis.Conclusions The increased serum VLDL-C and UA level,higher SYNTAX score and the history of previous PCI were independent predictors of ISR in patients with DM after coronary DES implantation.It provided new evidence for physicians to take measures to lower the risk of ISR for the better management of diabetic patients after PCI.
推荐文章
期刊_丙丁烷TDLAS测量系统的吸收峰自动检测
带间级联激光器
调谐半导体激光吸收光谱
雾剂检漏 中红外吸收峰 洛伦兹光谱线型
期刊_联合空间信息的改进低秩稀疏矩阵分解的高光谱异常目标检测
高光谱图像
异常目标检测 低秩稀疏矩阵分解 稀疏矩阵 残差矩阵
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 New predictors of in-stent restenosis in patients with diabetes mellitus undergoing percutaneous coronary intervention with drug-eluting stent
来源期刊 老年心脏病学杂志(英文版) 学科
关键词
年,卷(期) 2018,(2) 所属期刊栏目
研究方向 页码范围 137-145
页数 9页 分类号
字数 语种 英文
DOI 10.11909/j.issn.1671-5411.2018.02.011
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (48)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
1994(1)
  • 参考文献(1)
  • 二级参考文献(0)
1995(1)
  • 参考文献(1)
  • 二级参考文献(0)
2001(1)
  • 参考文献(1)
  • 二级参考文献(0)
2002(1)
  • 参考文献(1)
  • 二级参考文献(0)
2003(1)
  • 参考文献(1)
  • 二级参考文献(0)
2004(2)
  • 参考文献(2)
  • 二级参考文献(0)
2005(2)
  • 参考文献(2)
  • 二级参考文献(0)
2007(2)
  • 参考文献(2)
  • 二级参考文献(0)
2008(1)
  • 参考文献(1)
  • 二级参考文献(0)
2010(6)
  • 参考文献(6)
  • 二级参考文献(0)
2011(4)
  • 参考文献(4)
  • 二级参考文献(0)
2012(5)
  • 参考文献(5)
  • 二级参考文献(0)
2013(6)
  • 参考文献(6)
  • 二级参考文献(0)
2014(8)
  • 参考文献(8)
  • 二级参考文献(0)
2015(5)
  • 参考文献(5)
  • 二级参考文献(0)
2016(2)
  • 参考文献(2)
  • 二级参考文献(0)
2018(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
引文网络交叉学科
相关学者/机构
期刊影响力
老年心脏病学杂志(英文版)
月刊
1671-5411
11-5329/R
16开
北京市复兴路28号老年心脏病学杂志(英文版)编辑部
2004
eng
出版文献量(篇)
1086
总下载数(次)
0
总被引数(次)
2028
论文1v1指导