基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
Purpose: To compare the reproducibility of breath-holding and comfort between two biofeedback guidance methods (audio and visual) in a respiratory monitoring system. Method and Materials: An audio-feedback respiratory monitoring device, which was modified from a visual-feedback self-respiration monitoring system (Abches, APEX Medical Inc., Tokyo, Japan) previously developed by the authors’ group, was constructed. Twenty patients (13 men, 7 women;mean age, 68.5 years;range, 54 - 85 years) with tumors in the thorax or abdominal region were enrolled in the present study. Computed tomography images were acquired from all patients three times using the two (i.e., audio and visual) respiration monitoring devices. To evaluate the reproducibility of breath-holding, the distance between an anatomical landmark and the tumor position was measured. Furthermore, patients were asked which guidance method they preferred (visual or audio) for comfortable breath-holding. Results: The two guidance methods improved the reproducibility of breath-holding compared with free-breathing, and no significant overall differences between two methods were observed (the mean displacements of the landmark-tumor distance were 2.60 ±1.38 mm and 2.35 ±1.63 mm, for visual and audio guidance, respectively). In five patients, the magnitude of position displacement in the series of three computed tomography images under audio guidance was twice as large as the other under visual guidance. Audio guidance was preferred to visual guidance by 65% (13 of 20) of the patients. However, the reproducibility of breath-holding did not always correspond with patient preference. Conclusion: There were some individual differences in the reproducibility of the visual and audio guidance methods. More appropriate, individualized guidance methods for each patient would improve the reproducibility of breath-holding in respiratory motion management.
推荐文章
Visual Prolog的DDE机制研究
动态数据交换
逻辑程序设计
报表设计
Visual FoxPro环境字符排序探讨
Visual FoxPro
排序
精确比较
程序设计
Visual Basic语言数组概念解析
Visual Basic
数组
静态
动态
巧用Visual FoxPro制作套表打印
快速报表
报表布局
报表输出
打印
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Audio-Visual Biofeedback for Respiratory Motion Management: Comparison of the Reproducibility of Breath-Holding between Visual and Audio Guidance
来源期刊 现代物理(英文) 学科 医学
关键词 RESPIRATORY Motion MANAGEMENT
年,卷(期) 2018,(13) 所属期刊栏目
研究方向 页码范围 2286-2294
页数 9页 分类号 R73
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2018(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
RESPIRATORY
Motion
MANAGEMENT
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
现代物理(英文)
月刊
2153-1196
武汉市江夏区汤逊湖北路38号光谷总部空间
出版文献量(篇)
1826
总下载数(次)
0
总被引数(次)
0
论文1v1指导