基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
Background: 4D-CT has been used to localize the parathyroid adenomas and hyperplasia since 2006 as a second line study after TC-99 m MIBI and ultrasonography. However, multiple studies have shown that 4D-CT is a robust imaging method with high diagnostic accuracy, becoming increasingly popular among surgeons and radiologists. Purpose: To assess the diagnostic performance of 4D-CT scans to identify the pathologic gland(s), using pathology and intraoperative findings as gold standards. Methods: We analyzed patients with primary and secondary hyperparathyroidism who had intraoperative reports, pathology, parathyroid hormone levels, and preoperative 4D-CT. Histology, surgical findings, and decreased parathyroid hormone levels were used as gold standards. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), accuracy and 95% confidence interval were calculated. Fleiss’ kappa was used to assess the inter-observer agreement. Results: Sixty-seven patients were included. Sixty-two patients had a single adenoma, and five patients had a multiple gland disease (adenomas or hyperplasia). A total of 72 glands were proven to have parathyroid adenomas or hyperplasia. The sensitivity, specificity, PPV, NPV and accuracy are 85%, 97%, 96%, 87% and 91% for lateralization and 76%, 96%, 85%, 92% and 90% for quadrant localization, respectively in single-gland disease. The sensitivity, specificity, PPV, NPV and accuracy are 88%, 100%, 100%, 50% and 90% for lateralization and 71%, 100%, 100%, 60% and 80% for quadrant localization respectively in multiple-gland disease. Fleiss’ kappa value is 5.6 (moderate inter-observer agreement). Conclusion: 4D-CT is a robust method in the localization of hyperfunctioning parathyroid glands with high accuracy and at least moderate inter-observer agreement.
推荐文章
An experimental study on dynamic coupling process of alkaline feldspar dissolution and secondary min
Alkaline feldspar
Dissolution rate
Precipitation
Mineral conversion
Secondary porosity
一种改进的用于实现Observer模式的C++框架
设计模式
Observer
C++
signal
slot
Low net primary productivity of dominant tree species in a karst forest, southwestern China: first e
Biomass increment
Tree ring
Girth measurement
Karst evergreen and deciduous broadleaved forest
Allometric functions
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Diagnostic Performance and Inter-Observer Agreement of 4-Dimensional Computed Tomography Parathyroid Scans in Patients with Primary and Secondary Hyperparathyroidism
来源期刊 放射学期刊(英文) 学科 医学
关键词 COMPUTED TOMOGRAPHY PARATHYROID 4-Dimensional HYPERPARATHYROIDISM
年,卷(期) fsxqkyw_2019,(1) 所属期刊栏目
研究方向 页码范围 82-91
页数 10页 分类号 R73
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2019(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
COMPUTED
TOMOGRAPHY
PARATHYROID
4-Dimensional
HYPERPARATHYROIDISM
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
放射学期刊(英文)
季刊
2164-3024
武汉市江夏区汤逊湖北路38号光谷总部空间
出版文献量(篇)
256
总下载数(次)
0
论文1v1指导