基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
AIM:To evaluate dual Scheimpflug analyzer(Galilei) as a screening method for the diagnostic of gonioscopically narrow anterior chamber angles(ACA). METHODS:In 40 eyes of 40 patients with different ACA range, the ACA, anterior chamber volume(ACV) and anterior chamber depth(ACD) were analyzed using the dual Scheimpflug analyzer(Galilei G6 system). Correspondence between these parameters and Shaffer’s classification based on gonioscopy were studied. Receiving operator characteristic(ROC) curves and partition analysis were used to determine the efficacy of the Galilei system in screening for narrow angles. Agreement(Kappa statistics), sensitivity, and specificity for each eye, according to Galilei measures, were also assessed. RESULTS:Shaffer’s grade(from 0 to 4) were significantly associated with each of the measurements(P<0.001). In screening eyes with narrow angles with the Galilei, the area under the ROC curve was largest(0.90) when ACD was used as the reference, and partition analysis demonstrated that those eyes were most adequately partitioned with an ACD of 2.86 mm with 100% sensitivity and 80% specificity. CONCLUSION:The Galilei is a secure, repeatable and noncontact screening method for narrow angles. However it does not provide sufficient information about the ACA anatomy to be considered a substitute for gonioscopy.
推荐文章
Rapid estimation of soil heavy metal nickel content based on optimized screening of near-infrared sp
Heavy metal
Band extraction
Partial least squares regression
Extreme learning machine
Near infrared spectroscopy
The influence of urbanization on karst rivers based on nutrient concentration and nitrate dual isoto
Urbanization
Urban river
Nitrate isotopes
Southwestern China
Chengguan River
A re-assessment of nickel-doping method in iron isotope analysis on rock samples using multi-collect
Fe isotope
Ni-doping
Stable isotope
Precision and accuracy
Mass bias correction
Pseudo-high mass resolution
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Dual Scheimpflug imaging as a screening method for occludable angles-a comparison with gonioscopy
来源期刊 国际眼科杂志:英文版 学科 医学
关键词 GONIOSCOPY narrow ANTERIOR chamber ANGLE screening diagnostic accuracy ANGLE closure GLAUCOMA GLAUCOMA IMAGING
年,卷(期) 2019,(2) 所属期刊栏目
研究方向 页码范围 241-245
页数 5页 分类号 R
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2019(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
GONIOSCOPY
narrow
ANTERIOR
chamber
ANGLE
screening
diagnostic
accuracy
ANGLE
closure
GLAUCOMA
GLAUCOMA
IMAGING
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
国际眼科杂志:英文版
月刊
2222-3959
西安市友谊东路269号
出版文献量(篇)
2720
总下载数(次)
2
总被引数(次)
0
论文1v1指导