基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
AIM: To evaluate the interchangeability of keratometric and asphericity measurements provided by three measurement systems based on different optical principles.METHODS: A total of 40 eyes of 40 patients with a mean age of 34.1 y were included. In all cases, a corneal curvature analysis was performed with IOL-Master(IOLM), iDesign 2(ID2), and Sirius systems(SIR). Differences between instruments for flattest(K1) and steepest(K2) keratometric readings, as well as for magnitude and axis of corneal astigmatism were analyzed. Likewise, differences in asphericity(Q) between SIR and ID2 were also evaluated. RESULTS: Mean differences between devices for K1 were 0.20±0.21(P<0.001),-0.12±0.36(P=0.046) and-0.32±0.36 D(P<0.001) for the comparisons IOLM-SIR, IOLM-ID2 and SIR-ID2, respectively. The ranges of agreement for these comparisons between instruments were 0.41, 0.70, and 0.70 D. For K2, mean differences were 0.31±0.33(P<0.001),-0.08±0.43(P=0.265) and-0.39±0.38 D(P<0.001), with ranges of agreement of 0.65, 0.84, and 0.74 D. Concerning magnitude of astigmatism, ranges of agreement were in the limit of clinical relevance(0.49 D, P=0.011;0.55 D, P=0.386;0.43 D, P=0.05). In contrast, ranges of agreement were clinically relevant for astigmatic axis(26.68o, 33.83o and 18.37o, P≥0.121) and for Q between SIR and ID2(0.16, P<0.001). CONCLUSION: The keratometric corneal power, astigmatic axis and asphericity measurements provideby the three systems evaluated cannot be considered as interchangeable, whereas measurements of corneal astigmatism obtained with SIR and ID2 can be considered as interchangeable for clinical purposes.
推荐文章
Carbon dioxide emissions from the Three Gorges Reservoir, China
CO2 emissions
Three Gorges Reservoir
River-type reservoir
Source and composition of sedimentary organic matter in the head of Three Gorges Reservoir: a multip
Three Gorges reservior
Sedimentary organic matter
δ13C
Lignin phenols
Lipid biomarkers
基于Three.js的飞行仿真系统设计
Web三维可视化
WebGL
Three.js
数据驱动
三维仿真
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Interchangeability of corneal curvature and asphericity measurements provided by three different devices
来源期刊 国际眼科杂志:英文版 学科 医学
关键词 ASTIGMATISM CORNEAL TOPOGRAPHY KERATOMETRY CORNEAL ASPHERICITY
年,卷(期) gjykzzywb_2019,(3) 所属期刊栏目
研究方向 页码范围 412-416
页数 5页 分类号 R77
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2019(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
ASTIGMATISM
CORNEAL
TOPOGRAPHY
KERATOMETRY
CORNEAL
ASPHERICITY
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
国际眼科杂志:英文版
月刊
2222-3959
西安市友谊东路269号
出版文献量(篇)
2720
总下载数(次)
2
论文1v1指导