基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
AIM: To evaluate the clinical results, efficacy and safety of Ex-PRESS P200 glaucoma shunt implant in different types of medically uncontrolled glaucoma. METHODS: The study included 31 eyes of 31 patients that were unresponsive to medical antiglaucomatous therapy in whom Ex-PRESS P200 glaucoma shunt implantation was performed. The demographic characteristics of the patients, type of glaucoma, complete ocular examination results, number of antiglaucomatous drugs before and after surgery, early and late complications of surgery, additional surgical and nonsurgical medical interventions, and success rates were investigated from the patients’ files, retrospectively. RESULTS: The mean postoperative follow-up time was 16.4±7.5 mo. The preoperative mean corrected intraocular pressure(IOP) was 28.7±10.3 mm Hg and postoperative mean corrected IOP was 15.3±5.2 mm Hg(P<0.05) at the last visit. The mean IOP reduction was 39.9% when the preoperative and postoperative values of the last visits were compared. The average number of antiglaucomatous drug use decreased from 3.9±0.3 to 1.7±1.7 postoperatively(P<0.05). The use of antiglaucomatous medications at the last visit was more than in other studies in the literature. The most common complication was conjunctival leakage, which was seen in 7 patients. Other early complications were iris touch, intravitreal hemorrhage, hyphema, choroidal effusion, early transient hypotonia and corneal edema. One of the late complications was endophthalmitiswhich was seen in one case 6 mo after the operation, and the other late complication was opacification of the cornea in one patient. Twelve additional surgical operations associated to Ex-PRESS surgery and 3 bleb needling have done. At the last visit, the complete success rate was 32.3% and the qualified success rate was 77.5% in all patients. CONCLUSION: Ex-PRESS P200 glaucoma shunt implantation may be an effective procedure for medically uncontrolled glaucoma with significantly lower use of antiglaucomatous medications.
推荐文章
EX-PRESS青光眼引流钉植入术治疗原发性开角型青光眼疗效观察
EX-PRESS引流钉
原发性开角型青光眼
疗效
In-situ nitrogen fate in the vadose zone of different soil types and its implications for groundwate
Vadose zone
Silty-loam
Silty-clay-loam
Nitrogen transformation
Groundwater vulnerability
Stable isotopes
Ex-press青光眼引流器的临床应用观察
Ex-press青光眼引流器
开角型青光眼
复杂性青光眼
眼压
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Ex-PRESS implantation for different types of glaucoma
来源期刊 国际眼科杂志:英文版 学科 医学
关键词 GLAUCOMA Ex-PRESS IMPLANT GLAUCOMA SURGERY
年,卷(期) gjykzzywb_2019,(8) 所属期刊栏目
研究方向 页码范围 1290-1297
页数 8页 分类号 R779.6
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2019(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
GLAUCOMA
Ex-PRESS
IMPLANT
GLAUCOMA
SURGERY
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
国际眼科杂志:英文版
月刊
2222-3959
西安市友谊东路269号
出版文献量(篇)
2720
总下载数(次)
2
论文1v1指导