AIM: To explore whether the same corneal curvature parameters and anterior chamber depth measured by Pentacam and VX120 have a good consistency and can replace each other. METHODS: This study enrolled 140 eyes of 70 patients ranging in age from 19 to 53 y. All eyes underwent a comprehensive ophthalmologic examination including an anterior segment analysis with the VX120 system(Visionix-Luneau Technologies, Chartres, France) and Pentacam(Oculus Optikgerate GmbH) respectively. The comparison on corneal curvature parameters was done between Pentacam and VX120 using clustered signed rank test;the interclass correlation coefficients(ICC) with 95% confidence intervals(CI) was calculated for each parameter between Pentacam and VX120;the BlandAltman plot of each parameter was supplemented. RESULTS: The anterior corneal curvature measured by VX120 was Ks: 44.00±1.78 D, KsAt: 89.45±22.18, Kf: 42.84±1.58 D, KfAt: 93.91±79.34;which measured by Pentacam was Ks: 43.80±1.82 D, KsAt: 91.17±21.40, Kf: 42.61±1.64 D, KfAt: 91.16±78.69. There was statistical difference between Pentacam and VX120 for anterior corneal curvature parameter(P<0.001). The posterior corneal curvature measured by VX120 was Ks:-6.42±1.23 D, KsAt: 91.00±23.45, Kf:-5.85±1.24 D, KfAt: 95.93±79.11;which measured by Pentacam was Ks:-6.44±0.32 D, KsAt: 92.24±11.75, Kf:-6.01±1.05 D, KfAt: 74.43±80.64. There was statistical difference between Pentacam and VX120 for posterior corneal curvature parameters(P<0.001). Anterior chamber depth(ACD) measured by Pentacam and VX120was statistically different. Pentacam and VX120 achievedhigh consistency only on corneal anterior surface, including Ks and Kf. The ICCs were 0.96(95%CI: 0.95, 0.97) and 0.95(95%CI: 0.94, 0.97) respectively. For other corneal surface curvature parameters, all ICCs of between Pentacam and VX120 were below 0.87. Bland-Altman plots indicated oflow consistency of corneal surface curvature parameters measured by Pentacam and VX120. CONCLUSION: The corneal curvature parameters and anterior
推荐文章
VX120与KR1-W测量白内障角膜屈光参数的比较研究
Vx120
KR1-W
角膜屈光参数
波前像差
Methane production from rice straw carbon in five different methanogenic rice soils: rates, quantiti
13C-labeled rice straw
Methane production
Rice field soil
Microbial community
Oil geochemistry derived from the Qinjiatun–Qikeshu oilfields: insight from light hydrocarbons
Light hydrocarbons
Crude oil
Lishu Fault Depression
Geochemistry characteristic
Carbon dioxide emissions from the Three Gorges Reservoir, China
CO2 emissions
Three Gorges Reservoir
River-type reservoir
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Comparison of corneal curvature parameters obtained from two different instruments—Pentacam and VX120
来源期刊 国际眼科杂志:英文版 学科 医学
关键词 CORNEAL CURVATURE ANTERIOR CHAMBER depth PENTACAM VX120 interclass correlation COEFFICIENTS
年,卷(期) gjykzzywb_2019,(8) 所属期刊栏目
研究方向 页码范围 1311-1316
页数 6页 分类号 R770.4
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2019(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
CORNEAL
CURVATURE
ANTERIOR
CHAMBER
depth
PENTACAM
VX120
interclass
correlation
COEFFICIENTS
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
国际眼科杂志:英文版
月刊
2222-3959
西安市友谊东路269号
出版文献量(篇)
2720
总下载数(次)
2
论文1v1指导