作者:
基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
<strong>Background: </strong>Numerous studies have demonstrated increasing evidence for cataractogenesis at lower levels of ionizing radiation than previously believed, with some suggesting possible absence of a threshold. Genetic differences between individuals also result in increased susceptibility in some operators, who might not be aware. European occupational exposure limits have been reduced and operators are seeking protective measures. <strong>Objective: </strong>To evaluate the protective effect of a face-shield equipped suspended protection system (Zero-Gravity<span style="white-space:nowrap;"><sup><span style="white-space:nowrap;">&reg;</span></sup></span>, TIDI Products, Neenah, WI) along with adherence to safety practices against radiation dose to the eye lens for an interventional radiologist performing a wide variety of procedures. <strong>Materials and Methods:</strong> In this institutional review board-approved single-institution study, one interventional radiologist wore a highly sensitive personnel monitoring dosimeter badge on the cap near the left eye while performing 299 procedures (3690 fluoroscopy minutes) over 18 consecutive months while utilizing the suspended protection system along with adherence to other generally recommended safety practices and movement away from the field during angiographic power injections. Dosimetry reports and procedural information were retrospectively reviewed. <strong>Results: </strong>Total lens dose equivalent to the left eye over 18 months was 0.11 mSv (annualized dose = 0.073 mSv, or 7.3 mRem). The patient-dose-area product standardized dose of 0.00576 <span style="white-space:nowrap;"><span style="white-space:nowrap;"><span style="white-space:nowrap;">&mu;</span></span></span>Sv/Gy<span style="white-space:nowrap;"><span style="white-space:nowrap;">&sdot;</span></span>cm<sup>2</sup> is well below reports of conventional lead aprons, shields, and protective eyewear. <strong>Conclusion: </strong>Eye exposures were kept to near-background levels using the
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Occupational Eye Lens Radiation Dose While Performing Interventional Procedures over 18 Months Using a Face-Shield Equipped Suspended Radiation Protection System
来源期刊 放射学期刊(英文) 学科 数学
关键词 Lens Dose Reduction Radiation Safety Radiation-Induced Cataractogenesis Suspended Protection System
年,卷(期) 2020,(2) 所属期刊栏目
研究方向 页码范围 101-114
页数 14页 分类号 O17
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2020(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
Lens
Dose
Reduction
Radiation
Safety
Radiation-Induced
Cataractogenesis
Suspended
Protection
System
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
放射学期刊(英文)
季刊
2164-3024
武汉市江夏区汤逊湖北路38号光谷总部空间
出版文献量(篇)
256
总下载数(次)
0
总被引数(次)
0
论文1v1指导