基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
<strong>Background:</strong> Measuring optic nerve sheath diameter (ONSD), a relatively re-cent technique, allows an indirect and non-invasive diagnosis of intracranial hypertension. The ONSD ratio to eyeball transverse diameter (ETD) increases this reliability of the technique. The objective of this study was to determine the normal ONSD and its ratio with ETD in black African adults in Benin. <strong>Methods:</strong> A descriptive cross-sectional study was conducted between May 2019 and August 2019. Ultrasound ONSD and ONSD/ETD ratio were meas-ured in 210 healthy adults received in the medical imaging department of the Borgou and Alibori University Hospital Center in Benin. The ONSD corre-sponded to the average of 12 measurements (03 horizontal and 03 vertical for each eye) taken 3 mm behind the papilla. The transverse ETD corresponded to the average of 03 measurements. <strong>Results:</strong> The mean ONSD was 4.20 ± 0.28 mm (95% CI = [4.17;4.24] mm and 95th percentile = 4.70 mm). The mean ETD was 24.25 ± 1.10 mm. The ONSD/ETD ratio was 0.17 ± 0.01 (95% CI = [0.17;0.17] and 95th percentile = 0.19). There was no difference between ver-tical and horizontal ONSD and between right and left ONSD. The ONSD and the ONSD/ETD ratio were not correlated with any of the socio-demographic and anthropometric characteristics studied (sex, age, ethnicity, weight, height, body mass index, head circumference and waist circumference). The ONSD was associated with ETD (p < 0.001 and r = 0.55). <strong>Conclusion:</strong> An ONSD and an ONSD/ETD ratio respectively greater than 4.70 mm and 0.19 should sus-pect intracranial hypertension. The ONSD/ETD ratio may be a better indicator of HICT because of its small variation.
推荐文章
DIAMETER协议和RADIUS协议的比较
RADIUS协议
DIAMETER协议
认证/授权/计费服务器
Diameter协议对RADIUS协议性能缺陷的改进
RADIUS协议
Diameter协议
AAA
无线网络
Diameter信令网业务模型影响因素探讨
Diameter信令
Cx接口
Sh接口
Diameter对等端状态机研究及典型案例分析
Diameter协议
状态机
能力交换
选举
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Sonographic Measurement of the Optic Nerve Sheath Diameter (ONSD) and Eyeball Transversal Diameter (ETD) in Benin Healthy African Adults
来源期刊 放射学期刊(英文) 学科 社会科学
关键词 Optic Nerve Sheath Diameter Eye Transversal Diameter Ultrasound Intracranial Hypertension Adult BENIN
年,卷(期) 2020,(3) 所属期刊栏目
研究方向 页码范围 149-158
页数 10页 分类号 G35
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2020(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
Optic
Nerve
Sheath
Diameter
Eye
Transversal
Diameter
Ultrasound
Intracranial
Hypertension
Adult
BENIN
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
放射学期刊(英文)
季刊
2164-3024
武汉市江夏区汤逊湖北路38号光谷总部空间
出版文献量(篇)
256
总下载数(次)
0
总被引数(次)
0
论文1v1指导