基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
Guided implant surgery gained acceptance and credit in implant dentistry. The aim of this study is to find out and evaluate the relationship between implant size and success rate following computed tomography scan guided implant surgery. Sixty-four (36 females, 28 males) completely and partially edentulous patients aged between 42 and 65 years old were participated and fulfilled the inclusion criteria of the study. Two hundred and seventeen dental implants <u>(length: 10, 11.5, and 13 mm;Diameter: 3.3, 3.75, and 4.2 mm)</u> were placed using computed tomography scan guided implant surgery, 117 implants were placed in the maxilla, while 100 implants were placed in the mandible. The implants were evaluated for clinical parameters at 2, 4, and 12 weeks intervals after installation. <u>The overall success rate was 95.4%.</u> Clinical stability of the implant size (Diameter 3.3 mm, Length 10 mm) was the least as compared to other dimensions (<em>P</em> ≤ 0.05). Medium and large size implants (Diameter 3.75 and 4.2 mm, Length 11.5 and 13 mm) were the highest success rate in implant surgery. Implants width (diameter 3.3 mm) and length (10 mm) are best avoided in guided computed tomography surgery as compared with other implant sizes especially in atrophic bony areas. Computer-guided implant surgery remains exciting. Watchful planning and precise stability of the surgical guide are mandatory for successful protocol. Further investigations should be performed to assess such technique among dental patients from satisfactory point of view. Intensive cooperation between dentists and software engineering discipline should be aimed to maximize the success of such technique.
推荐文章
The partitioning patterns of nutrients between pods and seeds of Zanthoxylum fruits impacted by envi
Partitioning pattern
Nutritional quality
C:N ratio
Zanthoxylum fruits
Mean annual temperature
Mean annual precipitation
Isotherm and kinetic studies on the adsorption of humic acid molecular size fractions onto clay mine
Kaolinite
Montmorillonite
Leonardite humic acid
Humic acid fractions
Kinetics
Equilibrium
Kyanite far from equilibrium dissolution rate at 0–22℃ and pH of 3.5–7.5
Kinetics
Kyanite
Reaction rates
Mixed-flow reactor
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 The Relationship between Implant Size and Success Rate in Computer Guided Implant Surgery
来源期刊 生物医学工程(英文) 学科 医学
关键词 Guided Surgery Surgical Template ACCURACY Implants Dimension
年,卷(期) swyxgcyw_2020,(12) 所属期刊栏目
研究方向 页码范围 267-274
页数 8页 分类号 R73
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2020(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
Guided
Surgery
Surgical
Template
ACCURACY
Implants
Dimension
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
生物医学工程(英文)
月刊
1937-6871
武汉市江夏区汤逊湖北路38号光谷总部空间
出版文献量(篇)
252
总下载数(次)
1
论文1v1指导