基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
BACKGROUND Polyethylene(PE)particles produced by wear of the acetabular insert are thought to cause osteolysis and thereby aseptic loosening of the implant in total hip arthroplasty(THA).As highly cross-linked polyethylene(HXLPE)is presumed to give lower wear rates,in vivo studies are needed to confirm this.AIM To compare the wear of REXPOL,a HXPLE,with conventional PE within the first five years after implantation using Roentgen stereophotogrammetric analysis(RSA).METHODS Patients were randomised to receive either a HXLPE(REXPOL)or a conventional PE insert during primary THA.RSA images were obtained directly postoperative and after 6 wk,12 wk,6 mo,12 mo,24 mo and five years.Functional outcomes were assessed using the Hip Injury and Osteoarthritis Outcome Score and Harris Hip Score at baseline and five years after surgery.RESULTS The HXLPE(REXPOL)showed less wear in the latero-medial direction.Significant wear rates of conventional PE were seen in the latero-medial and center-proximal direction and in volume and corrected volume,whereas the REXPOL did not show these outcomes over time.Improvement from baseline in functional outcome did not significantly differ.CONCLUSION Total 3D wear is less in THAs inserted with a REXPOL inlay than a conventional PE inlay after five years.This study confirms,for the first,that the REXPOL HXLPE inlay is preferred to standard PE.
推荐文章
Geochronology and geochemistry of the five magmatic rocks in the Ningzhen region, China
Intermediate–acidic intrusive complexes
LA–ICP–MS zircon U–Pb dating
Geochemistry
Geodynamic setting
Ningzhen region
14-3-3/HIP-55复合体增强HIP-55蛋白稳定性
HIP-55蛋白,人
14-3-3蛋白质类
蛋白质相互作用
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Highly cross-linked versus conventional polyethylene inserts in total hip arthroplasty,a five-year Roentgen stereophotogrammetric analysis randomised controlled trial
来源期刊 世界骨科杂志:英文版 学科 医学
关键词 Highly cross-linked polyethylene Primary total hip arthroplasty Polyethylene wear Roentgen stereophotogrammetric analysis
年,卷(期) 2020,(10) 所属期刊栏目
研究方向 页码范围 442-452
页数 11页 分类号 R68
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2020(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
Highly
cross-linked
polyethylene
Primary
total
hip
arthroplasty
Polyethylene
wear
Roentgen
stereophotogrammetric
analysis
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
世界骨科杂志:英文版
月刊
2218-5836
北京市朝阳区东四环中路62号楼远洋国际中
出版文献量(篇)
404
总下载数(次)
1
总被引数(次)
0
论文1v1指导