基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
Purpose::To avoid potential problems of double-bundle anterior cruciate ligament reconstruction (ACLR), various modifications have been reported. This study analyzed a novel technique of modified double-bundle (MDB) ACLR without implant on tibial side in comparison to single-bundle (SB) ACLR.Methods::Eighty cases of isolated anterior cruciate ligament tear (40 each in SB group or MDB group) were included. SB ACLR was performed by outside in technique with quadrupled hamstring graft fixed with interference screws. In MDB group, ACLR harvested tendons were looped over each other at the center and free ends whipstitched. Femoral tunnel was created by outside in technique. Anteromedial tibial tunnel was created with tibial guide at 55 °. The anatomic posterolateral aiming guide (Smith-Nephew) was used to create posterolateral tunnel. With the help of shuttle sutures, the free end of gracillis was passed through posterolateral tunnel to femoral tunnel followed by semitendinosus graft through anteromedial tunnel to femoral tunnel. On tibial side the graft was looped over bone-bridge between external apertures of anteromedial and posterolateral tunnel. Graft was fixed with interference screw on femoral side in 10 ° knee flexion. International Knee Documentation Committee (IKDC), Tegner score, Pivot shift and knee laxity test (KLT, Karl-Storz) were recorded pre- and post-surgery. At one year magnetic resonance imaging (MRI) was done. Statistical analysis was done by SPSS software. Results::Mean preoperative KLT reading of (10.00 ± 1.17) mm in MDB group improved to (4.10 ± 0.56) mm and in SB group it improved from (10.00 ± 0.91) mm to (4.80 ± 0.46) mm. The mean preoperative IKDC score in MDB group improved from (49.49 ± 8.00) to (92.5 ± 1.5) at one year and that in SB group improved from (52.5 ± 6.9) to (88.4 ± 2.6). At one-year 92.5% cases in MDB group achieved their preinjury Tegner activity level as compared to 60% in SB group. The improvement in IKDC, KLT and Tegner scale of MDB group was superior to SB group. MRI confirmed graft integrity at one year and clinically at 2 years.Conclusion::MDB ACLR has shown better outcome than SB ACLR. It is a simple technique that does not require fixation on tibial side and resultant graft is close to native ACL.
推荐文章
重症医学科护理人员bundle循证知识、技能的现状调查
重症医学科
护理人员
bundle循证知识
技能
ITER Side 校正场线圈端部大圆弧模压成形及回弹分析
ITER Side校正场线圈
模压成形
回弹
有限元分析
适用于智能功率IC的700v Double-ResurfLdmos研究
双减少表面场
横向双扩散MOS晶体管
计算机辅助设计技术
Elemental characteristics and paleoenvironment reconstruction: a case study of the Triassic lacustri
Trace elements
Occurrence mode
Paleoenvironment
Zhangjiatan oil shale
Yanchang Formation
Ordos Basin
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Analysis of modified double-bundle anterior cruciate ligament reconstruction with implantless fixation on tibial side
来源期刊 中华创伤杂志英文版 学科
关键词 Anterior cruciate ligament reconstruction Fracture fixation Tibia
年,卷(期) 2020,(6) 所属期刊栏目 Original Article
研究方向 页码范围 341-345
页数 5页 分类号
字数 语种 中文
DOI 10.1016/j.cjtee.2020.04.007
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (17)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2003(1)
  • 参考文献(1)
  • 二级参考文献(0)
2012(1)
  • 参考文献(1)
  • 二级参考文献(0)
2013(3)
  • 参考文献(3)
  • 二级参考文献(0)
2014(2)
  • 参考文献(2)
  • 二级参考文献(0)
2015(2)
  • 参考文献(2)
  • 二级参考文献(0)
2016(2)
  • 参考文献(2)
  • 二级参考文献(0)
2017(3)
  • 参考文献(3)
  • 二级参考文献(0)
2018(2)
  • 参考文献(2)
  • 二级参考文献(0)
2019(1)
  • 参考文献(1)
  • 二级参考文献(0)
2020(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
Anterior cruciate ligament reconstruction
Fracture fixation
Tibia
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
中华创伤杂志(英文版)
双月刊
1008-1275
50-1115/R
大16开
重庆市渝中区大坪长江支路10号
78-81
1998
eng
出版文献量(篇)
1765
总下载数(次)
0
总被引数(次)
7300
论文1v1指导