基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
This paper uses a case study-based approach to comparatively evaluate the relationship between measured and perceived indoor environmental conditions in two office buildings, one naturally ventilated and one mechanically ventilated, located in south England. Environmental parameters (indoor and outdoor temperature and relative humidity, and indoor CO2 concentration) were continuously monitored at 5-minute intervals over a 19-month period (March 2017 to September 2018). During this time, occupant satisfaction surveys (both transverse and longitudinal) recorded occupant perceptions of their working environment, including thermal comfort, resulting in approximately 5700 survey responses from the two case studies combined. In the NV office, CO2 levels were high (often >2000 ppm) and indoor temperature was both high (>27 °C) and variable (up to 8 °C change in a working day). In contrast, the MV office environment was found to operate within much narrower temperature, RH and CO2 bands. This was particularly evident in the little seasonal variation observed in the CO2 levels in the MV office (rarely above 1200 ppm); whereas in the NV office, CO2 concentrations exceeded 2000 ppm on 12% of working days during the heating seasons and less than 1% in the non-heating season. Despite these differences in measured indoor environmental conditions, occupants' overall satisfaction with their environment was similar in both buildings. Occupants of the NV building were found to be more tolerant of higher indoor temperatures while neutral thermal sensation corresponded to a higher indoor temperature, indicating the role of adaptation. This has important implications for energy use in managing the indoor environment.
推荐文章
Genesis and soil environmental implications of intact in-situ rhizoliths in dunes of the Badain Jara
Rhizoliths
Calcification
Leptic regosols
Artemisia roots
Decomposition
Soil moisture
Magnetic Influences of Cement Dust on Soil in Industrial Area and Its Environmental Implications
Cement dust
Soil
Magnetic property
Environmental significance
中职Office教学与行业探究
中职教学
Office软件
应用
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Comparative evaluation of measured and perceived indoor environmental conditions in naturally and mechanically ventilated office environments
来源期刊 建筑模拟(英文版) 学科
关键词
年,卷(期) 2020,(5) 所属期刊栏目 RESEARCH ARTICLES
研究方向 页码范围 1021-1042
页数 22页 分类号
字数 语种 英文
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (23)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
1998(1)
  • 参考文献(1)
  • 二级参考文献(0)
1999(1)
  • 参考文献(1)
  • 二级参考文献(0)
2001(1)
  • 参考文献(1)
  • 二级参考文献(0)
2002(1)
  • 参考文献(1)
  • 二级参考文献(0)
2007(4)
  • 参考文献(4)
  • 二级参考文献(0)
2009(1)
  • 参考文献(1)
  • 二级参考文献(0)
2010(1)
  • 参考文献(1)
  • 二级参考文献(0)
2011(1)
  • 参考文献(1)
  • 二级参考文献(0)
2012(3)
  • 参考文献(3)
  • 二级参考文献(0)
2014(1)
  • 参考文献(1)
  • 二级参考文献(0)
2015(3)
  • 参考文献(3)
  • 二级参考文献(0)
2016(2)
  • 参考文献(2)
  • 二级参考文献(0)
2017(2)
  • 参考文献(2)
  • 二级参考文献(0)
2018(1)
  • 参考文献(1)
  • 二级参考文献(0)
2020(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
引文网络交叉学科
相关学者/机构
期刊影响力
建筑模拟(英文版)
双月刊
10-1106/TU
eng
出版文献量(篇)
459
总下载数(次)
0
论文1v1指导