基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
AIM:To compare intraocular pressure(IOP)measurements before and after laser in situ keratomileusis(LASIK)with a femtosecond laser for flap creation using ocular response analyzer(ORA)and Goldmann applanation tonometry,and to identify factors that may influence the preoperative and postoperative IOP.METHODS:A prospective study conducted on myopic patients who underwent LASIK using a femtosecond laser for flap fashioning.Enrolled patients were evaluated preoperatively,6 wk and 3 mo postoperatively for manifest refraction(MR),keratometric(K)readings and central corneal thickness(CCT)using a scheimpflug-based topography.Corneal resistance factor(CRF),corneal hysteresis(CH),Goldmann correlated IOP(IOPg)and corneal compensated IOP(IOPcc)were measured using ORA besides IOP assessment by Goldman applanation tonometry(GAT).RESULTS:There was a statistically significant decrease in measures of IOPg by 3.35±0.83 mm Hg,followed by GAT which decreased by 2.2±0.44 mm Hg,and the least affected by operation was IOPcc which decreased only by 0.87±0.1 mm Hg after 6 wk.After 3 mo follow up there was a statistically significant decrease in IOPcc which decreased only by 0.76±0.4 mm Hg,followed by IOP GAT by 1.6±0.5 mm Hg,and the most affected by operation was IOPg which decreased by 2.3±0.3 mm Hg.Correspondingly,there was a statistically significant decrease in CH and CRF after 6 wk and 3 mo.At 3 mo,the preoperative MR and preoperative GAT were prominent significant predictors of the postoperative GAT changes.The prediction equation was subsumed.CONCLUSION:IOP measurements and corneal biomechanical factors reduce significantly after LASIK with a femtosecond laser for flap creation.The IOPcc values are less influenced by changes in corneal properties than IOPg and GAT,indicating that IOPcc may provide the most reliable measurement of IOP after this procedure.
推荐文章
Thermodynamic properties of San Carlos olivine at high temperature and high pressure
San Carlos olivine
Thermodynamic property
Thermal expansion
Heat capacity
Temperature gradient
基于FEMTO的邻区列表自配置策略
Femto
邻区
自配置
侦听
SMILE与FS-LASIK术后眼压和角膜生物力学指标的变化比较
飞秒激光
飞秒激光小切口角膜基质透镜取出术
角膜生物力学
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Changes in corneal biomechanics and intraocular pressure following Femto-LASIK using Goldman applanation tonometry and ocular response analyzer
来源期刊 国际眼科杂志:英文版 学科 工学
关键词 intraocular pressure laser in situ keratomileusis femtosecond laser ocular response analyzer corneal biomechanics MYOPIA
年,卷(期) gjykzzywb_2020,(5) 所属期刊栏目
研究方向 页码范围 782-787
页数 6页 分类号 TN2
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2020(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
intraocular
pressure
laser
in
situ
keratomileusis
femtosecond
laser
ocular
response
analyzer
corneal
biomechanics
MYOPIA
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
国际眼科杂志:英文版
月刊
2222-3959
西安市友谊东路269号
出版文献量(篇)
2720
总下载数(次)
2
论文1v1指导