摘要:
Background Evaluation of left ventricular function plays a vital role in the study of hemodynamics in the circulatory system.This study investigated the feasibility of measuring left ventricular function in rats with catheterization at the apex of the heart.Methods Left carotid catheterization was used to monitor artery pressure,then right carotid-ventricular catheterization and apical catheterization were orderly performed in 20 SD rats to observe the changes of left heart function.Heart rate,carotid arterial pressure,left ventricular peak pressure,left ventricular end-diastolic pressure were recorded by the biological function experiment system,and differential calculations analyzed the systolic and diastolic rate of left ventricular pressure.Results The peak left ventricular pressure was statistically different between when measured by right carotid-ventricle catheterization and by catheterization at the apex of heart (120.7±14.46 mmHg vs.114.04±12.01 mmHg,P<0.05).There was a significant difference in the carotid artery pressure between when the left ventricular function was measured by right carotid-ventricular catheterization and by apical catheterization (115.6± 11.24 mmHg vs.108.07±12.33 mmHg,P< 0.05),while a different statistical scenario existed for the maximum increase rate of left ventricular pressure (6197.89± 1123.28 mmHg/s vs.5985.92± 1342.81 mmHg/s,P>0.05);30 min later,the left ventricular pressure and the maximum increase rate of left ventricular pressure were not significantly different between the first and second measurement measured by catheterization at the apex of heart (114.04± 12.01 mmHg vs.112.06±11.26 mmHg,5985.92±1342.81 mmHg/s vs.5700.86±598.97 mmHg/s,P>0.05).However,the maximum decline rate of left ventricular pressure was slightly lower compared with the previous measurement (5231.14±1302.57 mmHg/s vs.4862.72±610.49 mmHg/s,P<0.05).Conclusions It is feasible to evaluate cardiac function in rats by catheterization at the apex of heart,and it is superior to right carotid catheterization for its simpler operation,less bleeding risk,less operation time,and the measurement can be repeatedly conducted at least once.
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Left ventricular function in rats measured by apical catheterization
来源期刊 岭南心血管病杂志(英文版) 学科
关键词
年,卷(期) 2021,(1) 所属期刊栏目 BASIC RESEARCH
研究方向 页码范围 50-56
页数 7页 分类号
字数 语种 英文
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (12)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
1979(1)
  • 参考文献(1)
  • 二级参考文献(0)
1980(1)
  • 参考文献(1)
  • 二级参考文献(0)
1983(1)
  • 参考文献(1)
  • 二级参考文献(0)
1988(1)
  • 参考文献(1)
  • 二级参考文献(0)
2004(1)
  • 参考文献(1)
  • 二级参考文献(0)
2006(1)
  • 参考文献(1)
  • 二级参考文献(0)
2011(1)
  • 参考文献(1)
  • 二级参考文献(0)
2012(2)
  • 参考文献(2)
  • 二级参考文献(0)
2018(2)
  • 参考文献(2)
  • 二级参考文献(0)
2019(1)
  • 参考文献(1)
  • 二级参考文献(0)
2021(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
引文网络交叉学科
相关学者/机构
期刊影响力
岭南心血管病杂志(英文版)
季刊
1009-8933
44-1512/R
大16开
广州市东川路96号二楼233室
46-243
2000
eng
出版文献量(篇)
771
总下载数(次)
0
总被引数(次)
177
论文1v1指导