基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
We developed a novel portable and automated dissolution test analyzer for rapid and high precision in vitro dissolution testing of drugs.The analyzer consists of a flow-through-cell drug dissolution system,an automated sequential sampling system,a high-speed capillary electrophoresis (HSCE) system,and a data acquisition system.Combining the high-temporal resolution flow-gating sampling approach with HSCE,which has outstanding advantages of efficient separation and resolution,the analyzer can achieve rapid analysis and exhibits the ability in miniaturization for on-site assessment of different active pharmaceutical ingredients.To integrate the flow-through-cell dissolution system with HSCE,a specially designed flow-gating-injection (FGI) interface was employed.The performance of the analyzer was investigated by analyzing the dissolution of immediate-release drugs including single dose (amoxicillin dispersible tablets) and fixed dose combination (amoxicillin and clavulanate potassium) drug tablets with the high-temporal resolutions of 12 s and 20 s,respectively.The dissolution profiles of different active pharmaceutical ingredients could be simultaneously and automatically monitored with high repeatability and accuracy.The analyzer was successfully utilized for the pharmaceutical quality control and bio-relevant dissolution testing,as well as in vivo-in vitro correlation analysis.Our portable analyzer is miniaturized,convenient and of low-cost,and will provide a valuable tool for dissolution testing in pharmaceutical research and development.
推荐文章
Mechanism of accelerated dissolution of mineral crystals by cavitation erosion
Cavitation erosion
Mineral dissolution
Plastic deformation
Stepwave
Gibbs free energy
An experimental study of interaction between pure water and alkaline feldspar at high temperatures a
Alkaline feldspar
Autoclave
High-temperature and high-pressure experiments
Kyanite far from equilibrium dissolution rate at 0–22℃ and pH of 3.5–7.5
Kinetics
Kyanite
Reaction rates
Mixed-flow reactor
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Portable and automated analyzer for rapid and high precision in vitro dissolution of drugs
来源期刊 药物分析学报(英文版) 学科
关键词
年,卷(期) 2021,(4) 所属期刊栏目 Original Articles
研究方向 页码范围 490-498
页数 9页 分类号
字数 语种 英文
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (51)
共引文献  (1)
参考文献  (35)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
1963(1)
  • 参考文献(1)
  • 二级参考文献(0)
1973(1)
  • 参考文献(1)
  • 二级参考文献(0)
1978(1)
  • 参考文献(0)
  • 二级参考文献(1)
1983(1)
  • 参考文献(0)
  • 二级参考文献(1)
1985(2)
  • 参考文献(0)
  • 二级参考文献(2)
1988(1)
  • 参考文献(0)
  • 二级参考文献(1)
1989(2)
  • 参考文献(0)
  • 二级参考文献(2)
1991(2)
  • 参考文献(0)
  • 二级参考文献(2)
1992(3)
  • 参考文献(0)
  • 二级参考文献(3)
1993(2)
  • 参考文献(1)
  • 二级参考文献(1)
1994(2)
  • 参考文献(0)
  • 二级参考文献(2)
1995(1)
  • 参考文献(1)
  • 二级参考文献(0)
1996(3)
  • 参考文献(1)
  • 二级参考文献(2)
1998(2)
  • 参考文献(1)
  • 二级参考文献(1)
1999(5)
  • 参考文献(2)
  • 二级参考文献(3)
2000(3)
  • 参考文献(0)
  • 二级参考文献(3)
2001(3)
  • 参考文献(2)
  • 二级参考文献(1)
2002(3)
  • 参考文献(0)
  • 二级参考文献(3)
2003(2)
  • 参考文献(1)
  • 二级参考文献(1)
2004(2)
  • 参考文献(1)
  • 二级参考文献(1)
2005(2)
  • 参考文献(0)
  • 二级参考文献(2)
2006(2)
  • 参考文献(1)
  • 二级参考文献(1)
2007(4)
  • 参考文献(0)
  • 二级参考文献(4)
2008(3)
  • 参考文献(0)
  • 二级参考文献(3)
2009(2)
  • 参考文献(0)
  • 二级参考文献(2)
2010(7)
  • 参考文献(2)
  • 二级参考文献(5)
2011(2)
  • 参考文献(0)
  • 二级参考文献(2)
2012(1)
  • 参考文献(1)
  • 二级参考文献(0)
2013(3)
  • 参考文献(1)
  • 二级参考文献(2)
2014(1)
  • 参考文献(1)
  • 二级参考文献(0)
2015(2)
  • 参考文献(2)
  • 二级参考文献(0)
2016(1)
  • 参考文献(1)
  • 二级参考文献(0)
2017(1)
  • 参考文献(1)
  • 二级参考文献(0)
2018(7)
  • 参考文献(7)
  • 二级参考文献(0)
2019(6)
  • 参考文献(6)
  • 二级参考文献(0)
2021(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
引文网络交叉学科
相关学者/机构
期刊影响力
药物分析学报(英文)
双月刊
2095-1779
61-1484/R
大16开
西安市雁塔西路76号
1985
eng
出版文献量(篇)
639
总下载数(次)
0
论文1v1指导