基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
At present,most total knee replacement (TKR) prostheses on the market are designed according to the sizes of Caucasians.However,extensive studies have indicated that human anatomies differ among different ethnicities.A number of reports have indicated that Chinese TKR patients do not match with available prostheses.In this study,computed tomography (CT) images of 52 knees of Chinese men and women were used for anthropometric measurements.Index and geometric measurements were defined and used for correlation analysis.Key parameters from the measurement results were identified.Detailed geometries of knees were measured as coordinates.A deformable three-dimensional (3D) knee model based on anatomical coordinates correlating with the identified key parameters was generated.A pros-thesis was then designed according to the analyzed results.Surface matching analysis,bone resection analysis,and cadaveric trials were conducted and compared with commercial products to validate the proposed design.The femoral component designed by this study resulted in the highest accuracy (root mean square point-to-surface (RMS PS),(1.08 ± 0.20) mm) and lowest amount of resected bone volume(27412 mm3) in comparison with two commercial knee prostheses.This study suggests a new approach for population-based patient-specific femoral prosthesis design.With a single,easily acquired dimen-sion-namely,epicondyle width (ECW)--as input,a patient-specific femoral prosthesis can be designed according to the analyzed measured data and manufactured by additive manufacturing (AM) methods.Meanwhile,the reconstructed femoral condylar surface was compared with the femoral condylar surface in the original CT scanning data.The average RMS PS distance of the reconstructed femoral condylar sur-face among all data was (1.10 ± 0.18) mm,which is comparable to other statistical shape modeling meth-ods using multiple radiographs as input data.There is a need to develop an anthropometric-based knee prosthesis for the Chinese population.Based on the anthropometry of the Chinese population,our new design fits Chinese patients better and reserves more bone volume compared with current commercial prostheses,which is an essential step toward AM for personalized knee prostheses.
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Population-Based and Personalized Design of Total Knee Replacement Prosthesis for Additive Manufacturing Based on Chinese Anthropometric Data
来源期刊 工程(英文) 学科
关键词
年,卷(期) 2021,(3) 所属期刊栏目 Medical Additive Manufacturing—Article
研究方向 页码范围 386-394
页数 9页 分类号
字数 语种 英文
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2021(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
引文网络交叉学科
相关学者/机构
期刊影响力
工程(英文)
双月刊
2095-8099
10-1244/N
16开
北京市朝阳区惠新东街4号
80-744
2015
eng
出版文献量(篇)
817
总下载数(次)
8
论文1v1指导