基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
The indoor parameters are generally non-uniform distributed. Consequently, it is important to study the space cooling/heating load oriented to local requirements. Though the influence of indoor set point, heat sources, and ambient temperature of convective thermal boundary on cooling/heating load has been investigated in the uniform environment in previous research, the influence of these factors, particularly the convective heat gain/loss through a building envelope, on cooling/heating load of non-uniform environment has not yet been investigated. Therefore, based on the explicit expression of indoor temperature under the convective boundary condition, the expression of space cooling/heating load with convective heat transfer from the building envelope is derived and compared through case studies. The results can be summarized as follows. (1) The convective heat transferred through the building envelope is significantly related to the airflow patterns: the heating load in the case with ceiling supply air, where the supply air has a smaller contribution to the local zone, is 24% higher than that in the case with bottom supply air. (2) The degree of influence from each thermal boundary to the local zone of space cooling cases is close to that of a uniform environment, while the influence of each factor, particularly that of supply air, is non-uniformly distributed in space heating. (3) It is possible to enhance the influence of supply air and heat source with a reasonable airflow pattern to reduce the space heating load. In general, the findings of this study can be used to guide the energy savings of rooms with non-uniform environments for space cooling/heating.
推荐文章
The metallogenic environment of the Dounan manganese deposit, Southeast Yunnan, China: evidence from
Dounan manganese deposit
Metallogenetic environment
Mössbauer spectroscopy
Geochemistry
Oil geochemistry derived from the Qinjiatun–Qikeshu oilfields: insight from light hydrocarbons
Light hydrocarbons
Crude oil
Lishu Fault Depression
Geochemistry characteristic
Statistics matters in interpretations of non-traditional stable isotopic data
Isotopic data processing
Error propagation
Significant digits
Difference between means with uncertainties
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Comparison of space cooling/heating load under non-uniform indoor environment with convective heat gain/loss from envelope
来源期刊 建筑模拟(英文版) 学科
关键词
年,卷(期) 2021,(3) 所属期刊栏目 Building Thermal, Lighting, and Acoustics Modeling
研究方向 页码范围 565-578
页数 14页 分类号
字数 语种 英文
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (12)
共引文献  (1)
参考文献  (27)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
1960(1)
  • 参考文献(0)
  • 二级参考文献(1)
1998(1)
  • 参考文献(1)
  • 二级参考文献(0)
2000(1)
  • 参考文献(0)
  • 二级参考文献(1)
2002(4)
  • 参考文献(1)
  • 二级参考文献(3)
2003(1)
  • 参考文献(1)
  • 二级参考文献(0)
2004(3)
  • 参考文献(3)
  • 二级参考文献(0)
2008(2)
  • 参考文献(1)
  • 二级参考文献(1)
2009(1)
  • 参考文献(1)
  • 二级参考文献(0)
2010(1)
  • 参考文献(1)
  • 二级参考文献(0)
2011(1)
  • 参考文献(0)
  • 二级参考文献(1)
2012(3)
  • 参考文献(1)
  • 二级参考文献(2)
2013(1)
  • 参考文献(0)
  • 二级参考文献(1)
2014(2)
  • 参考文献(2)
  • 二级参考文献(0)
2015(1)
  • 参考文献(1)
  • 二级参考文献(0)
2016(2)
  • 参考文献(1)
  • 二级参考文献(1)
2017(3)
  • 参考文献(2)
  • 二级参考文献(1)
2018(7)
  • 参考文献(7)
  • 二级参考文献(0)
2019(4)
  • 参考文献(4)
  • 二级参考文献(0)
2021(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
引文网络交叉学科
相关学者/机构
期刊影响力
建筑模拟(英文版)
双月刊
10-1106/TU
eng
出版文献量(篇)
459
总下载数(次)
0
论文1v1指导