Objective::To investigate the efficacy of in-phase and quadrature (IQ) demodulation in electronic fetal heart rate monitoring (EFM) to reduce false reports of fetal heart rate (FHR) doubling or halving.Methods::This is a prospective cohort study. A total of 263 full-term pregnant women who delivered at Peking University Shenzhen Hospital between August 2019 and July 2020 were prospectively enrolled in the study. FHR monitoring began when the cervix was dilated to 2-3 cm and continued until delivery. Raw fetal Doppler audio signals and internal and external cardiotocography curves from internal electrode monitoring, EFM with conventional demodulation (external), and EFM with IQ demodulation (external) were acquired to compare FHR doubling and halving time. In cohort 1, FHR was compared between IQ demodulation and conventional demodulation. In cohort 2, FHR was compared between IQ demodulation, conventional demodulation, and internal FHR monitoring. Count data were statistically analyzed using the Chi-squared test, and measurement data were statistically analyzed using t-test for correlation coefficients, and Bland-Altman analysis for concordance ranges. Results::To compare IQ demodulation and conventional demodulation, 225 pregnant women were monitored for a total of 835,870 seconds. The beat-to-beat interval of FHRs in raw fetal Doppler audio signals was used as the reference. The results showed a doubling time of 3401 seconds (0.407%, 3401/835,870) and a halving time of 2918 seconds (0.349%, 2918/835,870) with conventional demodulation, compared to 241 seconds (0.029%, 241/835,870) and 589 seconds (0.070%, 589/835,870), respectively, with IQ demodulation. IQ demodulation reduced FHR doubling by approximately 93% (3160/3401) and FHR halving by approximately 80% (2329/2918) compared to conventional demodulation ( P < 0.01). Conclusion::EFM with IQ demodulation significantly reduces false FHR doubling and halving, with an efficacy similar to that of internal FHR monitoring.
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 The Efficacy of In-Phase and Quadrature Demodulation in Electronic Fetal Heart Rate Monitoring During Labor
来源期刊 母胎医学杂志(英文) 学科
关键词 Fetal monitoring Heart rate, fetal Doubling Halving IQ demodulation
年,卷(期) 2022,(2) 所属期刊栏目 Original Article
研究方向 页码范围 113-120
页数 8页 分类号
字数 语种 中文
DOI 10.1097/FM9.0000000000000127
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2022(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
Fetal monitoring
Heart rate, fetal
Doubling
Halving
IQ demodulation
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
母胎医学杂志(英文)
季刊
2096-6954
10-1632/R
16开
北京西城区东河沿街69号303室
2019
chi
出版文献量(篇)
122
总下载数(次)
0
论文1v1指导