摘要:
AIM: To evaluate the sources of variation influencing the microvascularization parameters measured by dynamic contrast-enhanced ultrasonography (DCE-US). METHODS: Firstly, we evaluated, in vitro , the impact of the manual repositioning of the ultrasound probe and the variations in flow rates. Experiments were conducted using a custom-made phantom setup simulating a tumor and its associated arterial input. Secondly, we evaluated, in vivo , the impact of multiple contrast agent injections and of examination day, as well as the influence of the size of region of interest (ROI) associated with the arterial input function (AIF). Experiments were conducted on xenografted B16F10 female nude mice. For all of the experiments, an ultrasound scanner along with a linear transducer was used to perform pulse inversion imaging based on linear raw data throughout the experiments. Semi-quantitative and quantitative analyses were performed using two signal-processing methods. RESULTS:In vitro , no microvascularization parameters, whether semi-quantitative or quantitative, were significantly correlated (P values from 0.059 to 0.860) with the repositioning of the probe. In addition, all semiquantitative microvascularization parameters were correlated with the flow variation while only one quantitative parameter, the tumor blood flow, exhibited P value lower than 0.05 (P = 0.004). In vivo , multiple contrast agent injections had no significant impact (P values from 0.060 to 0.885) on microvascularization parameters. In addition, it was demonstrated that semi-quantitative microvascularization parameters were correlated with the tumor growth while among the quantitative parameters, only the tissue blood flow exhibited P value lower than 0.05 (P = 0.015). Based on these results, it was demonstrated that the ROI size of the AIF had significant influence on microvascularization parameters: in the context of larger arterial ROI (from 1.17 ± 0.6 mm 3 to 3.65 ± 0.3 mm 3 ), tumor blood flow and tumor blood volume were correlated with the t
推荐文章
树体输入TDS克服板栗大小年结果的试验
树体输液
TDS
板栗
大小年
几种获取油藏动态参数方法的对比与分析
电缆地层测试器
动态参数
经济效益
基于混沌动态参数的散列函数
散列函数
混沌
动态参数
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 用动态提高对比的 ultrasonography 的 microvascularization 参数大小上的动脉的输入函数的影响
来源期刊 世界放射学杂志:英文版(电子版) 学科 医学
关键词 Dynamic CONTRAST-ENHANCED ULTRASONOGRAPHY ANGIOGENESIS Linear RAW data ARTERIAL input function Functional imaging
年,卷(期) 2012,(7) 所属期刊栏目
研究方向 页码范围 291-301
页数 11页 分类号 R310
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2012(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
Dynamic
CONTRAST-ENHANCED
ULTRASONOGRAPHY
ANGIOGENESIS
Linear
RAW
data
ARTERIAL
input
function
Functional
imaging
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
世界放射学杂志:英文版(电子版)
月刊
1949-8470
北京市朝阳区东四环中路62号楼远洋国际中
出版文献量(篇)
785
总下载数(次)
1
总被引数(次)
0
论文1v1指导