基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
Purpose/Objective: The primary objective of this FDA study is to evaluate the safety and efficacy of the ACT device (Adjustable Continence Therapy) in the treatment of female recurrent Stress Urinary Incontinence (SUI). The secondary objective is to evaluate the difficulty of placement and aspects of device adjustability. Materials and Methods: The Adjustable Continence Therapy (ACT) system (Uromedica, Inc., Plymouth, MN) consists of two silicone balloons providing urethral coaption and bladder neck support. Each balloon is attached to a titanium port buried in the labia allowing for post-operative adjustment of volume. Females with recurrent SUI with or without urethral hypermobility were evaluated at baseline and follow-up periods of 6 weeks, 3, 6, 9, 12 months and annually thereafter including urinalysis, a 3-day voiding diary, provocative pad weight test, direct visual stress test, Stamey score and validated questionnaires to assess severity of incontinence, voiding dysfunction, sexual function and quality of life. Results: During a 5 years period (2002-2007), 162 patients were implanted (mean age 67.6, range 31 - 94 years). Of these 162 patients 142, 90, 80, 56 and 31 patients completed the 1, 2, 3, 4 and 5 years follow-up respectively. One hundred and thirty five (83%) had failed at least one surgery for incontinence and 44% had failed 2 or more procedures prior to ACT implantation. Difficulty of ACT placement was rated mild in 62%, moderate in 30% and severe in 9%. Improvement in Stamey score of >1 grade was achieved in 75% (107/142) at 1 year, 76% (68/90) at 2 years, 86% (62/78) at 3 years, 93% (50/54) at 4 years and 83% (25/30) at 5 years. Dry rate (provocative pad weight 2 gms) was 51%, 62% , 76%, 76% and 76% at 1 through 5 years, and >50% improvement was achieved in 83%, 86%, 86%, 90% and 93%,respectively. IQoL improved from 37 at baseline to 71, 71, 75, 77 and 74 during the study, and optimal continence was achieved with a mean of 4 adjustments, and mean balloon volumes of 4.0 ml (1.0 - 11.5 ml). Comp
推荐文章
频域光学相干断层扫描测量青光眼视网膜神经纤维层厚度的可重复性研究
青光眼
视网膜神经纤维层厚度
频域光学相干断层扫描
Twitter的Follow关系和Retweet关系对比
在线社交网络
网络数据分类
同质性
推特网
SUI信道下Turbo均衡性能仿真研究
Turbo均衡
SUI信道
单载波调制
信道估计
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Five Years Follow-Up of Adjustable Continence Therapy (ACT) in the Treatment of Recurrent Female SUI
来源期刊 泌尿学期刊(英文) 学科 医学
关键词 FEMALE Urinary INCONTINENCE Implant BALLOON ADJUSTMENTS Safety Stamey Score
年,卷(期) 2013,(2) 所属期刊栏目
研究方向 页码范围 132-137
页数 6页 分类号 R73
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2013(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
FEMALE
Urinary
INCONTINENCE
Implant
BALLOON
ADJUSTMENTS
Safety
Stamey
Score
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
泌尿学期刊(英文)
季刊
2160-5440
武汉市江夏区汤逊湖北路38号光谷总部空间
出版文献量(篇)
324
总下载数(次)
0
总被引数(次)
0
论文1v1指导