基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
AIM: To experimentally investigate the acoustical behavior of different dual-mode nanosized contrast agents(NPCAs) for echographic medical imaging at low ultrasound(US) frequency. METHODS: We synthesized three different nanosized structures:(1) Pure silica nanospheres(SiNSs);(2) FePt-iron oxide(FePt-IO)-coated SiNSs; and(3) IOcoated SiNSs, employing three different diameter of SiNS-core(160, 330 and 660 nm). Tissue mimicking phantoms made of agarose gel solution containing 5 mg of different NPCAs in 2 mL-Eppendorf tubes, were insonified by a commercial echographic system at three different low US pulse values(2.5, 3.5 and 4.5 MHz). The raw radiofrequency signal, backscattered from each considered NPCA containing sample, has been processed in order to calculate the US average backscatter intensity and compare the acoustic behavior of the different NPCA types. RESULTS: The highest US contrast was exhibited by pure SiNSs; FePt-IO-coated SiNSs acoustical behavior followed a similar trend of pure SiNSs with a slight difference in terms of brightness values. The acoustic response of the examined NPCAs resulted function of both SiNS diameter and US frequency. Specifically, higher US frequencies determined higher value of the backscatter for a given SiNS diameter. Frequencydependent enhancement was marked for pure SiNSs and became less remarkable for FePt-IO-coated SiNSs, whereas IO-coated SiNSs resulted almost unaffected by such frequency variations. Pure and FePt-IO-coated SiNSs evidenced an image backscatter increasing with the diameter up to 330 nm. Conversely, among the types of NPCA tested, IO-coated SiNSs showed the lowest acoustical response for each synthesized diameter and employed US frequency, although a diameter-dependent raising trend was evidenced. CONCLUSION: The US characterization of magnetically covered SiNS shows that FePt-IO, rather than IO, was the best magnetic coating for realizing NPCAs suitable for dual mode imaging of deep organs, combining US and magnetic resonance imaging.
推荐文章
双模式化学推进技术发展研究
双模式推进系统
关键技术
发展策略
敞开式-土压式双模式TBM模式转换分析
双模式TBM
敞开式TBM
土压式TBM
隧道掘进
复合式TBM模式转换
一种双模式的运动估计算法
运动估计
粒子群算法
十字搜索法
双模式
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 为在低超声频率的双模式的成像的有磁力地涂的硅石 nanospheres
来源期刊 世界放射学杂志:英文版(电子版) 学科 医学
关键词 Ultrasound Magnetic resonance Nanocomposite DUAL-MODE IMAGING CONTRAST agent Diagnostic IMAGING
年,卷(期) 2013,(11) 所属期刊栏目
研究方向 页码范围 411-420
页数 10页 分类号 R310
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2013(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
Ultrasound
Magnetic
resonance
Nanocomposite
DUAL-MODE
IMAGING
CONTRAST
agent
Diagnostic
IMAGING
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
世界放射学杂志:英文版(电子版)
月刊
1949-8470
北京市朝阳区东四环中路62号楼远洋国际中
出版文献量(篇)
785
总下载数(次)
1
总被引数(次)
0
论文1v1指导